GigE CCD B/W Camera Instruction Manual Model BG030 / BG031 / BG080 / BG130 Thank you for purchasing our product. Before using this CCD camera, Please read through this instruction manual carefully in order to use this product correctly and safely. After reading, keep this instruction manual handy so that you can refer to, whenever you need it. Information contained in this document is subject to change without prior notice. D4211908A Copyright © 2012 TOSHIBA TELI CORPORATION, All rights reserved.
Contents Contents ........................................................................................................................1 Safety Precautions.........................................................................................................2 General Handing ..........................................................................................................................3 CASES FOR INDEMNITY (LIMITED WARRANTY) ....................................................................
Safety Precautions Before using this product, read these safety precautions carefully. Important information is shown in this Instruction Manual to protect users from bodily injuries and property damages, and to enable them to use the product safely and correctly. Please be sure to thoroughly understand the meanings of the following signs and symbols before reading the main text that follow, and observe the instructions given herein.
General Handing WARNING Unplug Stop operation immediately when any abnormality or defect occurs. If abnormal conditions are present, such as smoke, a burning smell, ingress of water or foreign matter, or if the equipment is dropped or malfunctions, fire or electric shock may result. Be always sure to disconnect the power cable from the wall socket at once and contact your dealer. Do not use the equipment in locations subject to water splashes. Otherwise, fire or electric shock may result.
CAUTION Instruction Observe the following when installing the equipment: ·Do not cover the equipment with a cloth, etc. ·Do not place the equipment in a narrow location where heat is likely to accumulate. Otherwise, heat will accumulate inside the equipment, possibly resulting in a fire. Do not place the equipment in locations subject to high moisture, oil fumes, steam, or dust. Otherwise, fire or electric shock may result.
CASES FOR INDEMNITY (LIMITED WARRANTY) We shall be exempted from taking responsibility and held harmless for damage or losses incurred by the user in the following cases. ● In the case damage or losses are caused by natural disasters, such as an earthquake and thunder, fire, or other acts of God, acts by a third party, deliberate or accidental misuse by the user, or use under extreme operating conditions.
RESTRICTION FOR USE ● Should the equipment be used in the following conditions or environments, give consideration to safety measures and inform us of such usage: 1. Use of the equipment in the conditions or environment contrary to those specified, or use outdoors. 2. Use of the equipment in applications expected to cause potential hazard to people or property, which require special safety measures to be adopted. ● This product can be used under diverse operating conditions.
Notes on using this product ● Handle carefully Do not drop the equipment or allow it to be subject to strong impact or vibration, as such action may cause malfunctions. Further, do not damage the connection cable, since this may cause wire breakage. ● Environmental operating conditions Do not use the product in locations where the ambient temperature or humidity exceeds the specifications. Otherwise, image quality may be degraded or internal components may be adversely affected.
●Do not expose the camera's image-pickup-plane to sunlight or other intense light directly Its inner CCD (charge-coupled device) might be damaged. ● Occurrence of moiré If you shoot thin stripe patterns, moiré patterns (interference fringes) may appear. This is not a malfunction. ● Occurrence of noise on the screen If an intense magnetic or electromagnetic field is generated near the camera or connection cable, noise may be generated on the screen. If this occurs, move the camera or the cable.
● Disposal When disposing of the camera, it may be necessary to disassemble it into separate parts, in accordance with the laws and regulations of your country and/or municipality concerning environmental contamination. This product is marked this symbol to subject to EU Waste Electrical & Electronic Equipment (WEEE) directive. Following information is only for EU-member states: The use of the symbol indicates that this product may not be treated as household waste.
环保使用期限标识,是根据电子信息产品污染控制管理办法以及,电子 信息产品污染控制标识要求(SJ/T11364-2006)、电子信息产品环保使用 期限通则,制定的适用于中国境内销售的电子信息产品的标识。 电子信息产品只要按照安全及使用说明内容,正常使用情况下,从生产 10 月期算起,在此期限内,产品中含有的有毒有害物质不致发生外泄或突 变,不致对环境造成严重污染或对其人身、财产造成严重损害。 产品正常使用后,要废弃在环保使用年限内或者刚到年限的产品时,请 根据国家标准采取适当的方法进行处置。 中华人民共和国 环保使用期限 部件名称 另外,此期限不同于质量/功能的保证期限。 The Mark and Information are applicable for People's Republic of China only.
Installation Before using this product, you shall install application software to display image and control registers of camera, and IP configuration tool for network setting. You can download the SDK for our GigE camera products (TeliGevSDK) from the Service & Support section of our website. User registration is necessary to use downloading service. Please make a user registration, or contact your dealer / distributor. ● TOSHIBA TELI CORPORATION Top Page http://www.toshiba-teli.co.jp/index.
Specifications Overview This Bees GigE B/W series is an integrated-(one-body)-type monochrome camera that adopts all pixel data readout inter line CCD. There are 4 models according to the sensor type. These are BG030 (VGA: 1/3 type), BG031 (VGA: 1/2 type), BG080 (XGA: 1/3 type), and BG130 (SXGA: 1/3 type). For video output, the Gigabit Ethernet®* interface standard "IEEE802.3ab" is adopted for high transfer rate, and it is easy to integrate into industrial equipment.
● GigEVision Ver 1.2 conformity This product is based on GigEVision Camera Interface Standard for Machine Vision Ver 1.2. ● GenICam Ver 2.3 conformity This product is based on GenICam Generic Interface for Cameras Ver 2.3. ● Binning mode This mode achieves high frame rate by adding two vertical lines or four vertical lines. ● Random Trigger Shutter The Random Trigger Shutter function provides images in any timing by input of an external trigger signal. Trigger control from PC is available as well.
Configuration The system configuration of this camera series is as follows; This camera does not include any accessories. Please prepare other equipments separately. ● Camera: This product. (Bees GigE) ● Camera mounting kit CPT8600 (*1): To fix a camera to a tripod; attach this to the bottom of the camera. ● LAN Cable (*2): This cable is used to connect the camera to host equipment. Ethernet packets (stream and control) are transmitted via this cable.
Connection ● In the case of supply DC+12V to the camera. ● In the case of supply PoE power to the camera. Notes on Connection: - Please confirm the power supply of the camera off when plugging in or pulling out the I/O Connector. It causes the breakdown. - If your camera is used in a system where its connectors are subjected to strong repetitive shocks, its connectors are possible to break down.
Connector Pin Assignment Rear View 1. Gigabit Ethernet Interface Connector RJ-45 Jack Pin No.
Notes on Power Supply: This camera has two ways of power supply, - Supply from LAN cable (PoE) - Supply from camera cable (DC+12V ±10%) If both PoE and DC+12V are connected, power is supplied from PoE. 17 / 69 Copyright © 2012 TOSHIBA TELI CORPORATION, All rights reserved. D4211908A http://www.toshiba-teli.co.jp/index.
Outline Drawing 18 / 69 Copyright © 2012 TOSHIBA TELI CORPORATION, All rights reserved. D4211908A http://www.toshiba-teli.co.jp/index.
General Specifications Model Name BG030 BG031 Imager BG080 BG130 All-pixel-data-readout interline transfer CCD Number of total pixels (H) × (V) 692 × 504 692 × 504 1077 × 788 1348 × 976 Number of effective pixels (H) × (V) 659 × 494 659 × 494 1034 × 779 1296 × 966 1/3 type 1/2 type 1/3 type 1/3 type 4.88 × 3.66 6.52 × 4.89 4.81 × 3.62 6.26 × 5.01 7.4 × 7.4 9.9 × 9.9 4.65 × 4.65 3.75 × 3.
Notes on combination of C-mount lens: - Depending on the lens you use, the performance of the camera may not be brought out fully due to the deterioration in resolution and brightness in the peripheral area, occurrence of a ghost, aberration and others. When you check the combination between the lens and camera, be sure to use the lens you actually use. - In addition, use a mounting screw free from defects and dirt. Otherwise, the camera may be unable to be removed.
I/O Specification ● Signal Specification - Trigger Input Input Circuit : Opto coupler input Level : Low 0 ~ 0.5V, High 3.3 ~ 24.
● Circuit diagram - Trigger Input - GPIO Output 22 / 69 Copyright © 2012 TOSHIBA TELI CORPORATION, All rights reserved. D4211908A http://www.toshiba-teli.co.jp/index.
● I/O Timing The received external trigger signal delays by internal circuit. And LINE2 output delays from LINE1 output by the difference of internal circuit. - Trigger Input (a) Negative (b) Positive Fig. Trigger Signal Input Delay EXT_TRIG_WIDTH: The pulse width of the external trigger input (more than 200µs). Toff: The delay time of falling edge. Ton: The delay time of rising edge. TRIG_IN_WIDTH: The pulse width of the trigger signal which is received inside of the camera.
- GPIO Output (a) ActiveLow (b) ActiveHigh Fig. GPIO Signal Output Delay Toff: LINE1~LINE2 falling delay time Ton: LINE1~LINE2 rising delay time Pull-up amplitude Toff [µs] Ton [µs] +3.3V 3 53.2 +12V 4 78.4 +24V 5 94.4 * Toff and Ton are typical value. * These values are changed in operating environment. 24 / 69 Copyright © 2012 TOSHIBA TELI CORPORATION, All rights reserved. D4211908A http://www.toshiba-teli.co.jp/index.
● Anti-chattering process for Trigger input In the characteristic of the open collector circuit, the signal is skewed. As a result, an invalid ingredient occurs. To filter out an invalid ingredient, this camera has the anti-chattering circuit. Therefore, Random Trigger Shutter operates only in the valid ingredient. Fig. Anti-chattering process 25 / 69 Copyright © 2012 TOSHIBA TELI CORPORATION, All rights reserved. D4211908A http://www.toshiba-teli.co.jp/index.
Timing Specification Image data outputs of this camera series are transferred with the UDP protocol of Gigabit Ethernet. Timing numerical value below is prescribed by absolute prerequisite that Bees GigE series use transmission band without restriction of other node. When there is a node transferring with Bees GigE concerned, it is not same the numerical value prescribed below.
● Random Trigger Shutter Operation EXT_TRIG INPUT DELAY TRIG_IN T3 Exposure GbE bus Image T1 TDLY1 T2 Timed mode (Image format: Mono8bit, all pixel readout) EXT_TRIG INPUT DELAY TRIG_IN T4 T3 Exposure GbE bus Image T1 TDLY1 T2 TriggerWidth mode (Image format: Mono8bit, all pixel readout) Model T3 [µs] T4 [µs] BG030 1.0 2.5 BG031 1.0 2.5 BG080 2.2 34.0 BG130 1.2 7.1 * T1 and T2 are the same as the value at the of the normal shutter setting. * T3 and T4 are typical value.
Typical Spectral Response * The lens characteristics and light source characteristics is not reflected in table. ● BG030 1.0 0.9 0.8 0.7 0.6 0.5 0.4 0.3 0.2 0.1 0 400 500 600 700 800 Wave Length [nm] 900 1000 ● BG031 28 / 69 Copyright © 2012 TOSHIBA TELI CORPORATION, All rights reserved. D4211908A http://www.toshiba-teli.co.jp/index.
● BG080 ● BG130 29 / 69 Copyright © 2012 TOSHIBA TELI CORPORATION, All rights reserved. D4211908A http://www.toshiba-teli.co.jp/index.
Operating Ambient Conditions ● Ambient conditions - Operating Assurance Temperature: 0°C ~ 40°C, Camera housing temperature: less than 50°C Humidity: 10% ~ 90% (no condensation) - Storage Assurance Temperature: -20°C ~ 60°C Humidity: 90% or less (no condensation) Notes on Heat Radiation: The temperature of camera housing must be kept less than 50 °C. Please provide sufficient heat radiation depending on your installation.
Functions This section introduces standard functions of Bees GigE series. This camera series provides following functions.
DeviceControl Registers of this category provide various information of the camera. And you can set the free user ID to the camera. ● Registers Register Visibility Access Expert R Returns the scan type. DeviceVendorName Beginner R Returns the vendor name. DeviceModelName Beginner R Returns the model name. DeviceManufacturerInfo Beginner R Returns the manufacturer information. DeviceVersion Beginner R Returns the device version.
Scalable Bees B/W series provide the scalable mode that can read out defined area of the screen. In the scalable mode, camera reads out only necessary area at the normal speed and reads out other area at high speed. The frame rate can be faster when the vertical height size is small. However, the frame rate cannot be faster only when the horizontal width size is small, due to the operation mechanism of the CCD sensor. Only single rectangle is selectable. Concave or convex shape is not selectable.
● Setting - Set image size and image start position Set the following value to “Width”, “Height”, “OffsetX”, “OffsetY” registers. Setting value is Integer type. “Width”, “Height” registers are image size setting. “OffsetX”, “OffsetY” registers are image start position setting.
Binning In the binning mode, a pixel is added with the neighboring pixel(s). This increases the sensitivity of the image. It’s alike scalable mode, the frame rate can be faster and Ethernet bandwidth occupation decrease. Fig. Binning operation (e.g. VGA) ● Registers Register Visibility Access Description BinningHorizontal Beginner R/W Set horizontal binning. BinningVertical Beginner R/W Set vertical binning. 35 / 69 Copyright © 2012 TOSHIBA TELI CORPORATION, All rights reserved.
● Setting - Set binning operation Set the following value to “BinningHorizontal”, “BinningVertical” registers. Setting value is Integer type. “BinningHorizontal” is the number of horizontal pixel(s) to add. And “BinningVertical” is the number of vertical pixel(s) to add. Model BG030 BG031 BG080 BG130 Minimum (*) 1(H)×1(V) 1(H)×1(V) 1(H)×1(V) 1(H)×1(V) Maximum 2(H)×2(V) 2(H)×2(V) 2(H)×2(V) 2(H)×2(V) * initial factory setting ● Note The range of register setting depends on camera model.
PixelFormat Select a pixel format of image stream data. This camera provides Mono8 bit and Mono10 bit Pixel format. ● Registers Register PixelFormat PixelSize Visibility Access Beginner R/W Expert R Description Selects a pixel format. Returns a bit size of image pixel. ● Setting - Selects a pixel format Set a following value to “PixelFormat” register. Setting value is Enumeration type.
TestImageSelector Bees B/W series support test pattern data output. Camera provides following Test patterns; Black White BrightGrey DarkGrey GreyHorizontalRamp Fig. Test pattern 38 / 69 Copyright © 2012 TOSHIBA TELI CORPORATION, All rights reserved. D4211908A http://www.toshiba-teli.co.jp/index.
● Registers Register TestImageSelector Visibility Access Beginner R/W Description Selects a test pattern. ● Setting - Select a test pattern output Set the following value to “TestImageSelector” register. Setting value is Enumeration type. The camera generates a test pattern.
AcquisitionControl Make a setting of image stream and control image stream output. Camera starts image stream output by receiving AcquisitionStrat command. And there are some registers that require camera to stop image stream output to change values. Acquisition frame rate is variable. Maximum acquisition frame rate depends on camera operation mode (scalable, binning, draft, link speed, etc.) ● Registers Register Visibility Access Description AcquisitionMode Beginner R Returns acquisition mode.
● Note Changing “AcquisitionFrameRate” register value is invalid during image stream data output. When exposure time setting is longer than frame rate setting, camera operation gives priority to exposure time setting. Notes on Frame Drops of Image: Depends on your PC or Gigabit Ethernet interface board configurations, images may not be captured normally (e.g. frame drops may occur). In this case, change to frame rate setting lower. 41 / 69 Copyright © 2012 TOSHIBA TELI CORPORATION, All rights reserved.
TriggerControl This section describes trigger control of AcquisitionControl category for the Bees GigE series. This camera series provides two kinds of exposure synchronization. 1. Normal Shutter mode : Free run operation (internal synchronization) 2. Random Trigger Shutter mode : Synchronized with external trigger input In Random Trigger Shutter mode, two kinds of trigger input are available. 1. Trigger signal via the I/O connector (HardwareTrigger) 2.
● Registers Register Visibility Access TriggerSelector Beginner R TriggerMode Beginner R/W TriggerSoftware Beginner W TriggerSource Beginner R/W Selects trigger source of Random Trigger Shutter. TriggerActivation Beginner R/W Selects trigger polarity of hardware trigger. Expert R/W Sets trigger delay. TriggerDelay Description Returns the type of trigger. Selects Random Trigger Shutter mode. Executes software trigger.
- Sets trigger delay (HardwareTrigger operation only) Set the following value to “TriggerDelay” register. Setting value is Float type. Adds delay time from trigger edge to exposure start. setting value TriggerDelay[µs] Minimum (*) 0.00[µs] Maximum 4095.00[µs] * initial factory setting ● Note Changing “TriggerMode”, “TriggerSource”, “TriggerActivation” registers value is invalid during image stream data output.
ExposureControl Bees GigE series is able to adjust exposure time by using electric shutter control. This camera series provides two kinds of exposure time control mode. - MANUAL mode : The exposure time is determined by “ExposureTime” register setting value. - AE mode : The exposure time is adjusted automatically by the photometry of the image. By combining AE mode and AGC (ALC mode), it can adjust a wide range of brightness fluctuation of the subject.
● Setting - Selects exposure control mode Set the following value to “ExposureMode” register. Setting value is Enumeration type. setting value Timed (*) TriggerWidth Manual exposure mode “ExposureTime” register control Trigger pulse width control * initial factory setting In Normal Shutter mode, the exposure time is determined by “ExposureTime” register value regardless of “ExposureMode” register setting. - Sets exposure time (timed mode only) Set the following value to “ExposureTime” register.
DigitalIOControl This section describes DigitalIOControl category for the Bees GigE series. This camera provides GPIO output selected by the register setting. And the polarity of the signal is able to switch by the register setting. The following chart shows the specifications of the selectable signals. Fig. Selectable signals ● Registers Register Visibility Access Description LineSelector Expert R/W LineMode Expert R Returns the direction of each Line signal.
● Setting - Select the Line of the I/O connector Set the following value to “LineSelector” register. The setting value is Enumeration type.
TimerControl This section describes TimerControl category for the Bees GigE series. This camera series is able to generate Timer0Active signal, derived from exposure start, by register setting. This signal can be used as strobe control signal. Fig. Timer0Active ● Registers Register Visibility Access Description TimerSelector Expert R TimerDuration Expert R/W Sets the width of Timer0Active signal. TimerDelay Expert R/W Sets the delay of Timer0Active signal.
- Set the delay of Timer0Active pulse Set the following value to “TimerDelay” register. Setting value is Float type. TimerDelay Dlay value Minimun (*) 0.00[µs] Maximum 4095.00[µs] * initial factory setting ● Note 50 / 69 Copyright © 2012 TOSHIBA TELI CORPORATION, All rights reserved. D4211908A http://www.toshiba-teli.co.jp/index.
EventControl This section describes EventControl category for the Bees GigE series. This camera series provides Event notifications of ALC and SoftwareTrigger information. ● Registers Register Visibility Access Description EventControl EventSelector Expert R/W Selects the type of Event notifications. EventNotification Expert R/W Sets the activation of Event notifications. EventFrameTriggerData EventFrameTrigger Expert R Returns Event ID of FrameTrigger type.
● Setting - Select the type of Event notifications Set the following value to “EventSelector” register. The setting value is Enumeration type. setting value Type of Event notification FrameTrigger (*) Information of SoftwareTrigger operation ALCLatestInformation Information of ALC update ALCConverged Information of ALC convergence * initial factory setting - Set the activation of Event notifications Set the following value to “EventNotification” register. The setting value is Enumeration type.
Gain This section describes Gain control of AnalogControl category for the Bees GigE series. This control adjusts the gain of the image. Fig. Gain This camera series provides two kinds of Gain control mode. - ManualControl (MANUAL) : The Gain value is determined by “Gain” register setting value. - AutoGainControl (AGC) : The Gain value is adjusted automatically by the photometry of the image.
● Setting - Set Manual Gain Set the following value to “Gain” register. Setting value is Float type. This setting value is valid only at Manual Gain mode setting. setting value Gain Minimum (*) 0.00 [dB] Maximum 18.00 [dB] * initial factory setting The formula of Gain value is as follows; - Select Gain control mode Set the following value to “GainAuto” register. Setting value is Enumeration type.
BlackLevel This section describes BlackLevel control of AnalogControl category for the Bees GigE series. This control adjusts the black level of the image. It is adjustable from -5% to +25% as white saturation level is 100%. However, when BlackLevel is lower than 0[%], the image level may not be saturated. Fig. Black Level ● Registers Register Visibility Access BlackLevelSelector Beginner R BlackLevel Beginner R/W Description Returns the luminance component of Black Level setting.
Gamma This section describes Gamma correction of AnalogControl category for the Bees GigE series. This function allows you to apply a gamma correction to the output images. Fig. Gamma correction ● Registers Register Gamma Visibility Access Beginner R/W Description Sets the Gamma correction. ● Setting - Set Gamma correction Set the following value to “Gamma” register. Setting value is Float type. Gamma setting value Minimum 0.45 Maximum (*) 1.
LUTControl This section describes LUTControl category for the Bees GigE series. This function allows you to apply the arbitrary LUT(input: 10bit, output: 10bit) to the output images. ● Registers Register Visibility Access Description LUTSelector Expert R LUTEnable Expert R/W Sets the activation of LUT process. LUTIndex Guru R/W Sets the input level of LUT process. LUTValue Guru R/W Sets the output level of LUT process. Returns the luminance component of LUT process.
TransportLayerControl This section describes TransportLayerControl category for the Bees GigE series. This camera series conforms to GigE vision 1.2 and GenICam 2.3 ● Registers Register Visibility Access PayloadSize Expert R GevVersionMajor Expert R GevVersionMinor Expert R Guru R Description Returns the payload size of the image data. Returns the version of the GigE Vision protocol. Returns the endian of the register.
Register Visibility Access Description GevMessageChannelCount Expert R Returns the number of message channels supported. GevStreamChannelCount Expert R Returns the number of stream channels supported. Guru R/W Sets the current heartbeat timeout [ms]. GevHeartbeatTimeout Initial factory setting: 3000[ms], Setting range: 0~4294967295[ms] GevTimestampTickFrequency Beginner R Returns the number of timestamp ticks [Hz].
● Setting - Set the IP Configuration Set the following value to “GevCurrentIPConfigurationLLA”, “GevCurrentIPConfigurationDHCP”, “GevCurrentIPConfigurationPersistentIP” registers. These setting values are Boolean type. Set these registers in conformity with your system. setting value IPConfiguration FALSE Inactive TRUE Active - Set the camera access privilege of an application. Set the following value to “GevCCP” register. The setting value is Enumeration type.
- Set the SCPD BlockStartDelay Set the following value to “GevSCPD”, “Teli_BlockStartDelay” registers. These setting values are Integer type. Fig. Packet delay 設定値 GevSCPD Minimum (*) Maximum Teli_BlockStartDelay 0 0 0xFFFFFFFF 0xFFFFE795 * initial factory setting ● Note 61 / 69 Copyright © 2012 TOSHIBA TELI CORPORATION, All rights reserved. D4211908A http://www.toshiba-teli.co.jp/index.
UserSetControl This section describes UserSetControl category for the Bees GigE series. You are able to save a user setting to the non-volatile memory of the camera. There are three user memory banks for user setting. By using user memory, you are able to restore frequently used settings at the time of next start-up. The following table is the list of registers applied by “UserSetLoad”/“UserSetSave”. Table.
● Setting - Select a bank of the user setting Set the following value to “UserSetSelector” register. The setting value is Enumeration type. Select the bank of user setting for “UserSetLoad” and “UserSetSave”. setting value Description Save Load Default (*) Memory bank to read initial factory setting data. × ○ UserSet1 Memory bank 1 for user setting. ○ ○ UserSet2 Memory bank 2 for user setting. ○ ○ UserSet3 Memory bank 3 for user setting. ○ ○ SafeMode Memory bank for maintenance.
ALCControl This section describes ALCControl category for the Bees GigE series. This camera series provides some registers to adjust the various parameter of ALC operation. When the camera operates at ALC, AE operation is prior to AGC operation. Fig. ALC operation ● Registers Register Visibility Access Description Teli_ALCPhotometricAreaSize Expert R/W Selects a photometric area size which is used to measure luminance.
● Setting - Set photometric area size for measuring luminance Set the following value to “Teli_ALCPhotometricAreaSize” register. The setting value is Enumeration type. setting value photometric area size Full (*) 100% (Full pixel) Medium 64% (H: 80% x V: 80%) Small 16% (H: 40% x V: 40%) * initial factory setting Fig. ALC Area - Set a value of the reference luminance Set the following value to “Teli_ALCReferenceLuminance” registers. These setting values are Integer type.
- Set a ExposureValue of ALC operation Set the following value to “Teli_ALCExposureValue” register. Setting value is Float type. When set “Teli_ALCExposureValue” register, add a correction value for a convergence value. ExposureValue setting value Minimum -2.00 [eV] Maximum +2.00 [eV] * initial factory setting = 0.00 [eV] Final convergence value by setting “Teli_ALCExposureValue” register is determined by the following formula.
- Set a range of AE operation Set the following value to “Teli_ALCExposureTimeMin”, “Teli_ALCExposureTimeMax” register. Setting value is Float type. AE mode operates at a range of a register value. You shall set “ExposureTimeMin” < “ExposureTimeMax”. If you set “ExposureTimeMax” longer than a frame rate period, a frame rate may be slower than the register setting. The range of register setting depends on camera model, and camera operation mode.
Warranty rules ● Warranty term Warranty term is 36 months after your purchase. We may assume the date of the purchase from our shipping date when the date is unidentified. ● Limited Warranty Free warranty is not applicable for the troubles, damages or losses caused by the cases of the followings, even if it is during the warranty term. 1. Natural exhaust, wear or degradation of a component parts 2. Handling against the instructions and conditions described in the instruction manual 3.
Repair ● Repair methods Exchange to a replacement or an equal function product. ● Repair request methods On the occasion of a repair request, please return the defective product with the the failure situation report sheet to be filled out. Please read the following instructions carefully. 1. Please return our product alone, taking out of your equipment in case that our product is installed to an equipment 2.
Bees series Failure situation report sheet Ver.2.04 In order to grasp the details of failure, please fill out the following information, and send us the defective product with this report sheet enclosed. (1) Customer information Company Name Department Telephone number Your Name E-Mail address FAX number Postal code number Address (2) Return address Please fill out this information, if the return addrrss is different from above address (1).