User manual

Phantom Help File96
© 2010 Vision Research - An AMETEK Company
trigger signal must be held in for it to be a valid trigger signal.
NOTE
The Trigger options are not available with the Phantom v4.1, v5.0, or v6.0 cameras.
pre-trigger pin is:
Pre-Trigger Pin Is specifies whether a TTL supplied input signal is to be used to toggle
Memory Gate or as a pre-trigger input signal.
NOTE
The MemGate options are not available with Phantom v4.1, v5.0, or v6.0 cameras.
Ready signal ends at:
Ready signal ends at instructs the connected-to camera to toggle off its READY signal either
the moment a Trigger signal has been detected by the camera or when the allocated
memory, in the selected camera, has completed capturing all the images to be recorded.
Miro/Strobe pin is:
The option allows the user to specify the signal type to be activated on the Auxiliary pin of
the capture connector.
NOTE
This option will only be available when connected to a Miro 3, Miro 3.1, Miro eX4, or Miro 4
camera.
Start In
The Start In command allows the end-user to specify the default operational state a camera
should be placed into when the user powers up the camera. The possible states include:
Idle
When selected this radio button instructs the camera to start in the Preview Waiting for
pre-trigger... mode. This means the end-user will have to click the Capture button, in
the Live Control Panel, to place the camera into the Preview + Recording… waiting for
trigger mode.
Capture
When selected this radio button instructs the camera to start in the Preview +
Recording… waiting for trigger mode.
NOTE
The Start in options are not available with the Phantom v4.1, v5.0, or v6.0 camera models.
Auto Exposure Selector
AutoExposure Enable Box
When enabled, (checked), the Auto Exposure feature will be enabled. The Auto Exposure
feature is extremely useful when conditions adversely effect setting the camera's exposure