User manual
Phantom Camera Control Application - Help 95
© 2010 Vision Research - An AMETEK Company
· If the camera is being clocked via another camera the delay MUST be set to a
minimum of 1µs greater than that defined in the clock source camera. or
· If a delay is required between the clock source pulse and the frame capture to provide
a phase shift in the timing.
This field MUST be defined when synchronizing multiple Phantom cameras using one
Phantom camera as the primary clock source.
Real Time Output
When enabled, checked, an image data will stream to an Image
3
.
Enable Box
When enabled, (checked), image data will stream from the selected camera to an attached
Image
3
.
Temperature
The Temperature informational fields indicate the operating temperatures of the selected
camera and its' sensor.
Cam:
This informational field displays the operating temperature of the camera.
NOTE
If the temperature of the Cam:, (camera), exceeds the camera's factory set threshold setting
the camera's cooling system will work harder to reduce the camera's operating temperature.
Sensor:
This informational field displays the operating temperature of the sensor.
NOTE
If the Sensors temperature rises above the sensor's factory set threshold setting, the
sensor's thermal expansion diodes will reduce the temperature of the sensor. If the sensor
temperature dips below the (sensor) factory set threshold setting, the sensor's thermal
expansion diodes will increase the temperature of the sensor.
Signals Button
The Signals button, when selected, opens the Analog and Binary Signal Acquisition dialogue
window used to define the parameters necessary for the Phantom Camera Control application
to process the signal information.
NOTE
This feature is not supported on the Phantom 65, HD, or Miro Series cameras.
Trigger
Rising/Falling Edge
When selected defines whether the leading edge or trailing edge of a TTL supplied
input trigger signal is to be used to trigger the camera. To select the leading or falling
edge click the Rising Edge or Falling Edge radio button respectively.
Filter Time (ms)
Filter Time instructs the Phantom camera to ignore a trigger signal if it is detected
before the specified Filter Time parameter. It also specifies the length of time the