4.1.5.2 Live Control Panel Components
The Live Control Panel is used to define the recording parameters for the selected Phantom camera,
and consist of the following components:
Group Lock Button
The Group Lock button is used to control and apply setting made to one camera associated to a
specific sub-group to all the cameras in the same sub-group automatically.
Camera: (Pull-Down Selection List)
The Phantom Camera Control application is capable of supporting up to 63 Phantom cameras.
This selection list window displays any user-defined Cameras Group sub-group, and the names
of the Phantom cameras presently connected to the Phantom Control Unit. Any changes made in
the Live Control Panel will be applied only to the Phantom camera or group of cameras specified
in this field, unless the Copy Parameters to..>All cameras command has been selected in the
Camera menu options.
Camera Settings Selector
The Camera Settings fields are used to display, reset, or synchronize the time stamp clock
information, set the bit depth of the active pixels, repartition or segment the DRAM of the camera,
perform CSR, (Current Session Reference), or Black Reference calibration adjustments.
The following is a brief description of the setup parameters associated with the Camera Settings:
Current Time
The Current Time field displays the date and time, an image will be time stamped with, in the
following format: hh:mm:ss Weekday Month Day Year.
Set Time.. Button
The Set button, when selected, opens the Set Camera Time dialogue window that
incorporates the following:
Computer Time
The fields associated with the Computer Time displays the date, time, and time zone of
the attached Phantom Control Unit. The active camera, or group of cameras
synchronize the time stamp to this control unit's local time setting, unless an IRIG-B
time source is being used as the clock reference.
The Computer Time is displayed in the following format: Field 1: Weekday , Month Day,
Year; Field 2: hh:mm:ss; Field 3: Time Zone, (The time difference from UTC -
Universal Time Code, formally GMT - Greenwich Means Time).
Current Camera Time
The fields associated with the Current Camera Time display the date, time, and time
zone of the selected Phantom Camera. The Current Camera Time and the Computer
Time should be synchronized when there is no IRIG-B clock source attached to the
camera. If an IRIG-B clock source is attached the Current Camera Time, should be
synchronized to the IRIG-B clock and will display the IRIG-B reference time.
The Current Camera Time is displayed in the following formats: Field 1: Weekday ,
Month Day, Year; Field 2: hh:mm:ss; Field 3: Time Zone (The time difference from