User manual
Phantom Help File62
© 2010 Vision Research - An AMETEK Company
3.2 Phantom Miro Touch-Sensitive LCD Cameras
This Quick Start Guide aims to provide 6 easy steps to get started using your Phantom Miro cameras
using the "Touch-Sensitive" LCD Screens.
For full details on the procedures described in the guides, please refer to the Phantom Miro Control
via "Touch-Sensitive" LCD Screens section.
STEP-BY-STEP PROCEDURES
Power Up the Phantom Camera
1.
Connect Capture Cable to Phantom camera.
2.
If using an external trigger, connect it to Trigger BNC, (Red), of the Capture Cable.
3.
Attach the Power Supply connector to the Phantom Miro camera, then
4.
Apply AC Power to the Power Supply Adapter.
5.
Hold the Power-On/Trigger button in, on the Phantom Miro camera for approximately 2
seconds, then
6.
Release the Power-On Trigger button.
NOTE
The start-up process takes approximately 15-seconds to complete. Once completed the
camera will be placed into the LIVE PRE, (Live Preview), Mode.
Prepare the Camera to Record a Cine File
1.
From the LIVE PRE Display Screen:
a.
Set the Resolution:
1)
Press directly on the Resolution field to select the field.
2)
Pressing directly on the value a second time increases the value.
3)
Pressing approximately 1/3 the screen height above the value to decrease the value.
4)
Repeat until the desired value is displayed.
NOTE
The Resolution of a Phantom Miro 1 is fixed at 640x480, and con not be changed.
b.
Set the Sample Rate:
1)
Press directly on the Sample Rate field to select the field.
2)
Pressing directly on the value a second time increases the value.
3)
Pressing approximately 1/3 the screen height above the value to decrease the value.
4)
Repeat until the desired value is displayed.
c.
Set the Exposure Time: