User manual
Phantom Help File36
© 2010 Vision Research - An AMETEK Company
3.
To prevent electrostatic damage that can occur when handling electronic equipment, use a
ground strap or similar device when performing module installation procedures.
4.
Before removing the DT3010 module from its anti-static bag you will need to discharge any
static electricity by holding the wrapped board on one hand while placing your other hand firmly
on a metal portion of the computer chassis.
5.
Do not force the DT3010 module into place. Moving the board from side to side during
installation may damage the bus connector. If you encounter resistance when inserting the
board, remove the board and try again.
6.
Selecting either the External option will cause the Phantom camera to lock up if the respective
input signal is not available. If there is no external or IRIG-B clock source the Internal option
MUST BE selected.
Sync Imaging (Camera Network Options)
1.
When utilizing the fsync feature, all cameras must be supplied an external trigger. If a soft-
trigger is used to trigger the cameras, Vision Research cannot guarantee that the cameras will
remain synchronized.