User manual

Phantom Camera Control Application - Help 193
© 2010 Vision Research - An AMETEK Company
5.
Set the Master Camera Serial (0=none) parameter to 0, (zero) for all cameras.
6.
Specify the desired Frame Delay:
a.
Enter the delay time required between the clock source pulse and the frame capture to
provide a phase shift in the timing, alternately
b.
Leave this setting at its default of 1µs if no delay is to be added.
4.2.5.3.5 Enable Real Time Output Parameters
To enable image data to stream from the selected camera to an attached Image
3
.
1.
Click the Live Control Panel Tab.
2.
Click on Advanced Settings, then
3.
Enable Real Time Output.
4.2.5.3.6 Define the Acquisition Signals
A Phantom Camera and the Phantom Camera Control application can utilize the SAM-3 (Signal
Acquisition Module-3) system to tag image frames with signal information supplied through a data
acquisition unit such as the DT9802 and DT3010 Series Data Acquisition Modules. This mechanism
is an extension of the time stamp storage system; these data tags are treated very much like time
stamps and the event signal.
To use the SAM-3, (Signal Acquisition Module-3), system with a Phantom camera and the Phantom
Camera Control application, the DT9802 or DT3010 Series Device Drivers must be loaded in the
Phantom Control Unit. A Phantom Camera and the Phantom Camera Control application can utilize
the SAM-3 (Signal Acquisition Module-3) system to tag image frames with signal information supplied
through a data acquisition unit such as the DT9802 and DT3010 Series Data Acquisition Modules.
This mechanism is an extension of the time stamp storage system; these data tags are treated very
much like time stamps and the event signal.
To use the SAM-3, (Signal Acquisition Module-3), system with a Phantom camera and the Phantom
Camera Control application, the DT9802 or DT3010 Series Device Drivers must be loaded in the
Phantom Control Unit.
The following process only describes the steps to define the Phantom Camera Control application
signal inputs, for the complete installation and setup process see, Accessories, Peripherals, and
Miscellaneous Features>Sam-3, (Signal Acquisition Module-3), Installation.
1.
Click the Live Control Panel Tab.
2.
Click on Advance Settings.
3.
Click the Signals button.