User manual
Phantom Camera Control Application - Help 189
© 2010 Vision Research - An AMETEK Company
maximum sample rate for the defined resolution. The TTL input pulse must be connected to
the BNC (Bayonet Neill-Concelman) connector marked Sync on the attached Capture cable
or breakout box.
NOTE
When External Sync Imaging is selected the Cine Settings>Sample Rate field will be
disabled.
5.
Enter the 4-digit serial number of the master clock source camera in the Master Camera Serial
(0=none) field.
6.
Set the Frame Delay, of all slave cameras, cameras accepting the master cameras provided
clock, to at least 1µs greater than that of the master camera.
NOTE
The 4-digit serial number of a camera can be found on the side of each Phantom camera.
7.
Ensure the Exposure time setting, of the Externally timed cameras, does not exceed the
maximum Exposure time of the master clock source camera.
8.
Ensure that the Post Trigger value of the master clock source camera is set to a value that is
one frame greater than the Post Trigger setting of the Externally timed cameras.