User's Manual
Introduction
Thanks for choosing the Vision’s wireless CO detector of the home security device. This detector is a
Z-Wave™ enabled device (interoperable, two-way RF mesh networking technology) and is fully
compatible with any Z-Wave™ enabled network and it’s security framework. Every mains powered
Z-Wave™ enabled device acts as a signal repeater and multiple devices result in more possible
transmission routes which helps eliminate “RF dead-sports”.
Z-Wave™ enabled devices displaying the Z-Wave™ logo can also be used with it regardless of the
manufacturer, and ours can also be used in other manufacturer’s Z-Wave™ enabled networks. This
detector is designed to sense CO that comes into the detector chamber and send Z-Wave™ signal
when the detector detects a certain density of CO, the horn of CO detector will sound. When the
device is secure included into Z-Wave network, above communication will be encrypted.
Product Description and Specification
*** For indoor use only ***
Specification:
Package Content:
Protocol: Z-Wave™ (ZM5202)
1pc
ZS 6301-5 CO Detector
Frequency Range:
865.22MHz (ZS6301IN-5)
868.10MHz (ZS6301MY-5)
868.42MHz (ZS6301EU-5)
869.00MHz (ZS6301RU-5)
908.42MHz (ZS6301US-5)
916.00MHz (ZS6301IL-5)
919~923MHz (ZS6301KR-5)
919.80MHz (ZS6301HK-5)
922~926MHz (ZS6301JP-5)
921.42MHz (ZS6301BR-5)
1pc
Bracket Holder
Operating Range: Up to 100 feet line of sight
Operating Temp.: 0°C~ 50°C (32°F~122°F)
Relative Humidity: 10% to 95%RH
Battery: DC 4.5V (3 x AA1.5V for Alkaline)
Sensitivity: Meet with both UL2034 and EN50291
Size: (Diameter)125 mm x (Depth)35mm
Z-Wave™ Command Classes:
COMMAND_CLASS_NOTIFICATION_V4
COMMAND_CLASS_ZWAVEPLUS_INFO_V2
COMMAND_CLASS_SECURITY
COMMAND_CLASS_VERSION_V2
COMMAND_CLASS_MANUFACTURER_SPECIFIC_V2
COMMAND_CLASS_DEVICE_RESET_LOCALLY
COMMAND_CLASS_ASSOCIATION_V2
COMMAND_CLASS_ASSOCIATION_GRP_INFO
COMMAND_CLASS_POWERLEVEL
COMMAND_CLASS_BATTERY
COMMAND_CLASS_WAKE_UP_V2
COMMAND_CLASS_FIRMWARE_UPDATE_MD_V2
Installation
Notice: If you are installing the entire Z-Wave™ system for the first time, please refer to
the installation guide of Z-Wave™ Interface Controller before installing ZS6301.
1. Remove the bracket from the detector by rotating it counter-clockwise.
2. Place the bracket where you are going to install the detector. In each of keyhole
slots, draw a mark to locate plastic anchor and screw. Using a 3/16-inch (5mm) drill
bit, drills two holes at the marks and insert plastic anchor, and attached the bracket
by using the screws.
3. Open the battery cover to insert the batteries, and then replace the cover. Fix the
detector with bracket by rotating it clockwise.
4. For “Inclusion” in (adding to) a network: Put the Z-Wave™ Interface Controller into
“inclusion” mode, and following its instruction to add the ZS6301-5 to your controller.
To get in the “inclusion” mode, the distance between detector and controller is
suggested to be in one meter. By power on to get included for first time or press the
test switch of ZS6301-5 once to be included. After be included, the red LED will go
on.
For “Exclusion” from (removing from) a network: Put the Z-Wave™ Interface
Controller into “exclusion” mode, and following its instruction to delete the
ZS6301-5 from your controller. Press the test switch of ZS6301-5 once to be
excluded.
For “Awake” mode: To leave “Sleep” mode, please press the test switch once, the
device will send “Wake Up Notification” after 10 seconds.
For “Association”: After “Awake” mode, then put the Z-Wave ™ Interface
Controller into “Association”, and following its instruction to associate the ZS6301-5
with other device. Afterward the ZS6301-5 will get into “Sleep” mode for power
saving. Grouping identifier =1, One association group supports 5 nodes.
“Association” is used for other grouping devices chain reaction.
For “Auto Wake-up” mode: The users could use Wake-Up command to change the
auto wake up from 10 minutes to 1 week.