User's Manual
Introduction
Thanks for choosing the Vision’s wireless shock sensor of the home security device. This
sensor is a Z-Wave™ enabled device (interoperable, two-way RF mesh networking
technology) and is fully compatible with any Z-Wave™ enabled network and its’ security
framework. Every mains powered Z-Wave enabled device acts as a signal repeater and
multiple devices result in more possible transmission routes which helps eliminate “RF
dead-spots”
Z-Wave™ enabled devices displaying the Z-Wave™ logo can also be used with it
regardless of the manufacturer, and ours can also be used in other manufacturer’s
Z-Wave™ enabled networks. This sensor detects the vibrations made by an intruder
trying to break a window or door, and also detect tamper situations, it will send Z-Wave™
signal when vibrations or tamper situations are detected. When the device is secure
included into Z-Wave network, above the communication will be encrypted.
Product Description and Specification
*** For indoor use only ***
Specification:
Package Content
Protocol: Z-Wave™ (ZM5202)
Frequency Range:
865.22MHz (ZS5101N-5)
868.10MHz (ZS5101MY-5)
868.42MHz (ZS5101EU-5)
869.00MHz (ZS5101RU-5)
908.42MHz (ZS5101US-5)
916.00MHz (ZS5101IL-5)
919~923MHz (ZS5101KR-5)
919.80MHz (ZS5101HK-5)
922~926MHz (ZS5101JP-5)
921.42MHz (ZS5101BR-5)
Operating Range: Up to 100 feet line of sight
Operating Temp.: -15°C~ 60°C (5°F~140°F)
Battery: Panasonic CR123A * 1PC
1pc ZS 5101-5 Shock sensor
1pc Bracket Holder
1pc Adhesive tape for sensor
3pc Screw
1pc CR123A Lithium Battery
1pc Installation & Operation
Manual
Z-Wave Command Classes:
COMMAND_CLASS_ASSOCIATION_GRP_INFO
COMMAND_CLASS_ASSOCIATION_V2
COMMAND_CLASS_BATTERY
COMMAND_CLASS_DEVICE_RESET_LOCALLY
COMMAND_CLASS_FIRMWARE_UPDATE_MD_V2
COMMAND_CLASS_MANUFACTURER_SPECIFIC_V2
COMMAND_CLASS_NOTIFICATION_V4
COMMAND_CLASS_POWERLEVEL
COMMAND_CALSS_SECURITY
COMMAND_CLASS_VERSION_V2
COMMAND_CLASS_WAKE_UP_V2
COMMAND_CLASS_ZWAVEPLUS_INFO_V2
Alarm Version 1
Notification Version 4
Alarm Type
Vibration detected
0x02
Tamper Switch
0x03
Alarm Level
ON : 0xFF
OFF: 0x00
Notification
Type
Vibration detected
0x07
Tamper Switch
0x07
Notification
Event
Vibration detected
ON : 0x02
OFF: 0x00
Tamper Switch
Open:0x03
Close:0x00
Event
Parameter
Vibration detected
0x02
Tamper Switch
0x03
Installation
Notice: If you are installing the entire Z-Wave™ system for the first time, please refer to
the installation guide of Z-Wave™ Interface Controller before installing ZS 5101-5 Shock
Sensor.
1. Install Battery: Use care when installing the battery. Press the locking tab on the top
sensor cover, and then gently pull up the cover. Observe the correct polarity before
insert the battery.
2. After insert the battery, the LED will start to flash slowly, which means the sensor
has not yet been “inclusion”.
3. For “Inclusion” in (adding to) a network: Put the Z-Wave™ Interface Controller
into “inclusion” mode, and following its instruction to add the ZS 5101-5 to your
controller. To get in the “inclusion” mode, the distance between sensor and
controller is suggested to be in one meter. Press the program switch of ZS 5101-5
for 1 second at least to be included. The LED on the ZS 5101-5 should go off, if not,
please try again.