User's Manual
8. Humidity Report- If the present humidity is different with the sensor record and exceed the
setting program, the sensor will report the present humidity.
Multilevel Sensor Report
Sensor Type
0x05
Scale
0x00 (%)
Size and Precision
2
9. Light Report- If the present illumination is different with the sensor record and exceed the
setting program, the sensor will report the present illumination.
Multilevel Sensor Report
Sensor Type
0x03
Scale
0x00 (%)
Size and Precision
2
10. Factory Default Reset: Remove cover to trigged tamper switch, LED flash once & send out
Alarm Report. Press Program Switch 10 times within 10 seconds, ZP3111 will send the “Device
Reset Locally Notification” command and reset to the factory default. (Remark: This is to be used
only in the case of primary controller being inoperable or otherwise unavailable.)
11. All the rest commands depend on Z-Wave standard.
Operation
1. Using adhesive tape to mount ZP3111 at 2 meters above surface. To enhance proper
operation, place ZP3111 on the location which can detect the room widely.
2. Walk in front of ZP3111, sensor will send Basic set On (0xFF) , Red LED willl flash
once and please refer to status report as table below.
3. If no movement detected in three minutes (default is 3 minutes - based on user’s
configuration setting, refer Table 1 (Parameter 5) will send Basic Set OFF (0x00), Red
LED will flash once, and refer to table for status.
4. The ZP3111 sensor equipped with tamper switch. If the tamper switch is triggered (or
remove the cover), the ZP3111 sensor will send Alarm Report, LED will flash once and
refer to table for status.
5. If the tamper switch is closed (or closed the cover), ZP3111 will send Alarm Report,
and refer to table for status.
Alarm V1
(Movement & Tamper
Switch)
Notification V4
(Movement)
Notification V4
(Tamper Switch)
Alarm Type
0x07
Alarm Level
0x00 (No movement
after 3 mins)
0xFF (Motion
detected)
Notification Type
0x07
0x07
Notification
Event
0x08(Motion
Detected)/
0x00 (no movement
after 3 mins)
0x03(remove cover)/
0x00 (cover closed)
Notification
Event Parameter
0x08
0x03
6. Support OTA Firmware update from controller. Please refer to your controller manual
and use COMMAND_CLASS_FIRMWARE_UPDATE_MD_V2. To proceed the OTA
process. Once OTA function success, please make sure to exclude the device &
include again before using the device.