User's Manual
Configuration – Temperature
Size
VALUE
Default
Parameter 1
1
°C
0x00
°C(0x00)
°F
0x01
Parameter 2
1
1~50 (Set up from
0.1°C~5°C)
1 (°C)
Configuration – Humidity
Size
VALUE
Default
Parameter 3
1
1~50 (Set up from
1%~50%)
10%
Configuration – Light
Size
VALUE
Default
Parameter 4
1
0,5~50 (Set up from 0
for Off or 5%~50%)
10%
Configuration – Motion Sensor:
Size
Value
Parameter 5
1
1 ~ 255 (unsigned decimal) Minutes
(default: 3 minutes)
Parameter 6
1
1 ~ 7
(default: 4)
(Table 1)
(Parameter 5) Re-trigger duration: User can change value from 1 to 255 minutes to setup
the re-trigger time when there is no movement detected in the period of time. Default is 3
minutes.
(Parameter 6) Infrared sensor sensitivity adjustment, 7 levels sensitivity, 1 = most
sensitive, 7 = most insensitive, default values= 4
Configuration – LED Mode:
Size
Value
(Default: Mode 3)
Parameter 7
1
1 ~ 3 (Mode 1 ~ Mode 3)
Mode 1 LED Turn Off (Both Temp./PIR Trigger)
Mode 2 Temp. (Breathing Light Mode)
PIR (Quick Flash)
Mode 3 LED Quick Flash (Temp./PIR Trigger)
(Caution: Mode 2 will shorten the battery life due to the Breathing Light Mode.)
Installation
Notice: If you are installing the entire Z-Wave
TM
system for the first time, please refer to the
installation guide of Z-Wave
TM
Interface Controller before installing ZP3111.
1. Release cover tab to open the cover and insert two AAA battery into the battery
compartment and close the cover back to sensor.
2. Press the program switch, the LED will flash 5 times which means the sensor has not been
“included” yet or flash once which means the sensor has been “included” already.
3. For “Inclusion (Auto-Inclusion)” in (adding to) a network: To add the ZP3111 to your
Z-Wave network (inclusion), place your Z-Wave primary controller into inclusion mode and
the distance between sensor and controller is suggested to be in one meter. Press the
Program Switch of ZP3111 for sending the NIF. After sending NIF, Z-Wave will send the
auto inclusion, otherwise, ZP3111 will go to sleep after 20 seconds.
4.
For “Exclusion” from (removing from) a network: To remove the ZP3111 from your
Z-Wave network (exclusion), place your Z-Wave primary controller into “exclusion” mode,
and following its instruction to delete the ZP3111 to your controller. Press the Program
Switch of ZP3111 once to be excluded.
For “Association”: Press the program switch for sending NIF, the LED will flash once and
send the Wake Up Notification in 5 seconds. Put the Z-Wave
TM
Interface Controller into
“association”, and following its instruction to associate the ZP3111 with other device.
Support grouping identifier=1. Support one association group (5 nodes).
“Association” is
used for other grouping devices chain reaction. Red LED will flash once when trigger.
5.
Auto Wake Up:
Use “Wake Up” command to set up the awaking time (from 10 minutes to 1 week) and send
the wake up notification to controller
6. Battery Capacity Detection:
* Use “Battery Get” command to have the battery capacity back in %
* It will detect the battery capacity automatically
* Low Battery Auto Report when power is lower than 2.6V +/- 0.1V
7. Temperature-If the present temperature is different with the sensor record and exceed the
setting program, the sensor will report the present temperature. LED flash every 3 minutes
to represent the temperature or wake up by press the Program SW.
Temperature
LED Color
Under 15°C
Green
15~23°C
Blue
23~28°C
Yellow/YellowGreen
28~36°C
Purple
Over 36°C
Red
Multilevel Sensor Report
Sensor Type
0x01
Scale
0x00 (°C)
0x01 (°F)
Size and Precision
2
- 3 -
- 4 -