User's Manual
based on user’s configuration setting) will send Basic Set (Off) and
Wave™ Interface Controller, and the
4. Awake Mode:
It will be triggering after opening the front cover (refer Table 2), also the red LED will
keep on lasting 10 seconds and ZP3102 will send “Wake Up Notification” after 10
seconds.
5. Auto Wake Up:
Use “Wake Up” command to set up the awaking time (from 10 minutes to 1 week) and
send the wake up notification to controller
6.. Battery Capacity Detection:
* Use “Battery Get” command to have the battery capacity back in %
* It will detect the battery capacity automatically
* Low Battery Auto Report when power is lower than 2.6V +/- 0.1V
7. Temperature Report:
The user needs to get the controller for receiving the current temperature except when
the temperature +2
°C or -2°C degree then the sensor will automatically report to the
controller. (ZP3102 will send the Multilevel Sensor Report to Controller)
8. Configuration Command Class:
Byte
Value
Parameter 1
1
1 ~ 255 (unsigned decimal) Minutes
(default: 3 minutes)
Parameter 2
1
0x00 (Celsius) / 0x01 (Fahrenheit)
(default: 0x00)
Parameter 3
1
1 ~ 7
(default: 4)
Parameter 4
1
-10 ~ -1, 0 ~ 10 (signed decimal in Celsius)
(0xF6~0xFF, 0x0~0xA, default: 0x00)
(Table 1)
(Parameter 1) Re-trigger duration: User can change value from 1 to 255 minutes to
setup the re-trigger time when there is no movement detected in the period of time.
Default is 3 minutes.
(Parameter 2) Celsius / Fahrenheit switching function.
(Parameter 3) Infrared sensor sensitivity adjustment, 7 levels sensitivity, 1 = most
sensitive, 7 = most insensitive, default values= 4
(Parameter 4) User Defined Celsius Adjustment , for user's own choice
9. Using adhesive tape to mount ZP3102 at 2 meters above surface. To enhance proper
operation, place ZP3102 on the angle which can detect the room widely. The solid
area means the detector’s coverage range.
10. Factory Default Reset: Remove cover to trigged tamper switch, LED ON & send out Alarm
Report. Press Program Switch 10 times within 10 seconds, ZP3102 will send the “Device
Reset Locally Notification” command and reset to the factory default. (Remark: This is to be
used only in the case of primary controller being inoperable or otherwise unavailable.)
11. All the rest commands depend on Z-Wave standard.
Operation
1. Walk in front of ZP3102, sensor will send Basic set On (0xFF) , LED willl flash once
and please refer to status report as table below.
2. If no movement detected in three minutes (default is 3 minutes - based on user’s
configuration setting, refer Table 1, Parameter 1) will send Basic Set OFF (0x00), LED
will flash once, and refer to table for status.
3. The ZP3102 sensor equipped with tamper switch. If the tamper switch is triggered (or
remove the cover), the PIR sensor will send Alarm Report, LED will go solid, and refer
to table for status.
4. If the tamper switch is closed (or closed the cover), ZP3102 will send Alarm Report,
LED will go off, and refer to table for status.
5. Alarm report willl not be send if there is no association set. Before closing the tamper
switch (or closed the cover), the sensor is under “Awake” mode.
-3-