User Manual

Introduction
Thanks for choosing the Visions wireless deadbolt door lock of the home security device.
This deadbolt lock is a Z-Wave
TM
enabled device (interoperable, two-way RF mesh
networking technology) and is fully compatible with any Z-Wave
TM
enabled network.
Every main powered Z-Wave
TM
enabled device acts as a signal repeater and multiple
devices result in more possible transmission routes which helps eliminate RF
dead-sport.
Z-Wave
TM
enabled devices displaying the Z-Wave
TM
logo can also be used with it
regardless of the manufacturer, and ours can also be used in other manufacturers
Z-wave
TM
enabled networks. This deadbolt lock monitors who and when the door is
opened and closed and send Z-Wave
TM
signal to the controller. User can also control
which user code can only unlock the door at certain period of time. It is Security Enable
Z-Wave
TM
deadbolt lock and a Security Enabled Z-Wave Controller must be used to fully
utilize the product.
Product Description and Specification
* For outdoor use *
* For indoor use *
Package Content:
1pc
2pcs
1pc
1pc
1pc
4pc
ZM 1701
Door Key
Operation Manual
Installation Manual
Drilling Template
AA Energizer Battery
Operation
-1-
Operating with Z-Wave
TM
Network:
If you are installing the entire Z-Wave
TM
system for the first time, please refer to the
installation guide of Z-Wave
TM
Interface Controller before installing ZM 1701.
1. Remove battery cover and observe the correct polarity before insert the batteries.
2. For Inclusion in (adding to) a network: Put the Z-Wave
TM
Interface Controller into
inclusion mode, and following its instruction to add the ZM 1701 into your controller.
To get in the Inclusion mode, the distance between ZM1701 and controller is
suggested to be in one meter. Press Keypads © manually turn
the Turn Piece from inside to be included. User shall hear one long beep sound and
controller shall indicate device is successfully inclusion into network. Inclusion will
take approximately 2 minutes, please wait the Inclusion finished before doing next
step.
For Exclusion from (removing from) a network: Set up the Z-Wave
TM
Interface
Controller into exclusion mode, and following its instruction to delete the ZM 1701
from your controller. Press Keypads ©manually turn the Turn
Piece from inside to be excluded.
For “Association”: the Z-Wave™ Interface Controller set “Association”, and
following its instruction to associate the ZM1701 with other device. Support one
group (5 nodes). ZM1701 will report back every time lock and unlock status.
3. How to setup the user code, how to delete user code or delete all user code, please
follow the Z-Wave
TM
Interface controllers instruction.
4. ZM 1701 supports the following class command:
COMMAND_CLASS_ASSOCIATION
COMMAND_CLASS_BASIC,
COMMAND_CLASS_BATTERY,
COMMAND_CLASS_DOOR_LOCK
COMMAND_CLASS_DOOR_LOCK_LOGGING
COMMAND_CLASS_USER_CODE,
COMMAND_CLASS_MANUFACTURER_SPECIFIC
COMMAND_CLASS_SCHEDULE_ENTRY_LOCK,
COMMAND_CLASS_SECURITY
COMMAND_CLASS_VERSION
COMMAND_CLASS_TIME_PAPAMETERS
Note: BASIC_SET not mapping & BASIC_GET mapping DOOR_LOCK_OPERATION_
GET (for door lock status report)
Operation the deadbolt lock:
1. Press © and enter a valid user code and press to unlock the door. User shall
hear one beeps and lights green. If code is invalid, user shall hear one beeps and
lights red.
2. If user press invalid code during process, please press © to start over.
3. ZM 1701 Electronic Deadbolt Lock supports up to 13 sets of User code (including
Master code). Each number combination can be 4 digits to 10 digits.
4. ZM 1701 Electronic Deadbolt Lock supports up to 50 schedule slots (year, month, day,
time) to Entry lock for all user in the system.
-2-
Turn Piece