User's Manual

Introduction
Thanks for choosing the Visions wireless siren & strobe alarm of the home security device.
This siren is a Z-Wave enabled device (interoperable, two-way RF mesh networking
technology) and is fully compatible with any Z-Wave enabled network. Every main
powered Z-Wave enabled device acts as a signal repeater and multiple devices result in
more possible transmission routes which helps eliminate RF dead-sports”.
Z-Wave enabled devices displaying the Z-Wave logo can also be used with it
regardless of the manufacturer, and ours can also be used in other manufacturers
Z-Wave enabled networks. This product will sound a loud siren and flash a strobe light
when an alarm message or alert is received on any Z-Wave enabled network.
Product Description and Specification
*** For indoor use only ***
Specification:
Package Content:
Protocol: Z-Wave (ZM3102N)
Frequency Range:
868.42MHz (ZM1601EU)
908.42MHz (ZM1601US)
921.42MHz (ZM1601BR)
920.00MHz~928.00MHz (ZM1601JP)
865.22MHz (ZM1601IN)
Operating Range: Up to 100 feet line of sight
Loud Audible Alarm: > 105Db@1meter
LED Strobe Lighting
Operating Temp.: -15°C~ 60°C (5°F~140°F)
Battery: 4pcs x AA Energizer Batteries
Z-Wave Command Classes:
COMMAND_CLASS_BASIC
COMMAND_CLASS_BATTERY
COMMAND_CLASS_CONFIGURATION
COMMAND_CLASS_MANUFACTURER_SPECIFIC
Note: COMMAND_CLASS_BASIC Mapping
ZM 1601 Siren
Adhesive tape
Screw
AAEnergizer Batteries
Installation & Operation
Manual
Installation
Note: If you are installing the entire Z-Wave™ system for the first time, please refer to the
installation guide of Z-Wave™ Interface Controller before installing ZM 1601.
1. Remove the bracket from the siren by press the locking tab, and then gently slide
up the siren. Observe the correct polarity before insert the batteries.
2. Using the screws or adhesive tape to affix the bracket on the chosen location.
3.
Slide back the front cover, and then the LED should go off
.
4. For Inclusion in (adding to) a network: Put the Z-Wave Interface Controller
into inclusion mode, and following its instruction to add the ZM 1601 to your
controller. To get in the inclusion mode, the distance between siren and controller
is suggested to be in one meter. Open the bracket and press the program switch of
ZM 1601 for 1 second at least & release to be included. After setting, the LED
Setting Lighting should go off, if not, please try again.
For Exclusion from (removing from) a network: Set up the Z-Wave Interface
Controller into exclusion mode, and following its instruction to delete the ZM 1601
from your controller. Press the program switch of ZM 1601 for 1 second at least &
release to be excluded.
Note: LED setting light will flash (orange color) continuously in Exclusion condition.
5. Configuration command class:
Parameter 0: Siren/ Strobe Mode, 1 Byte Value: 0=siren and Strobe enable
(default), 1=siren only, 2= Strobe only.
Parameter 1: Alarm auto stop time command, 0=30 seconds (default), 1= 60 secs,
2= 120 secs, 3= siren will not automatically stop.
Operation
1. Normal operation, the LED light will not on.
2. Self-Protection Mode: After put back the bracket over 5 seconds, ZM 1601 will enter
Self-Protection Mode. If the back cover is opened will trigger the Self-Protection
Mode. The alarm time is default 30 seconds.
3. Users controller should support Z-wave FLiRS technology.
4. Alarm Mode (Its the status of alarm triggered): Its based on the users
configuration setting of LED flash ON/OFF and Siren ON/OFF.
Note: for Default setting-Siren/Strobe Mode-Parameter will be All enable; Alarm
Auto Stop Time-Parameter will be 30 sec.
5. For safety reason, replace new battery whenever ZM 1601 is triggered.