User's Manual
Note:
a. LED setting light will flash continuously in Exclusion condition.
b. All user and network settings will be cleared and the device reset to factory
defaults when the device is excluded.
For “Association”: removing the back cover of the ZM1601 to get into “Awake”
mode, then put the Z-Wave Interface Controller into “association”, and following its
instruction to association the ZM1601 with other device. Close the back cover
after “association” done, afterward the ZM1601 will get into “Sleep” mode for power
saving. Support one association group (5 nodes).
6. Configuration command class:
Byte
Value
Parameter 1
(Siren/Strobe Mode)
1
0 (All Enable) - Default
1 (Siren Only)
2 (Strobe Only)
Parameter 2
(Alarm Auto Stop Time)
1
0 (30 seconds) - Default
1 (60 seconds)
2 (120 seconds)
3 (Will Not Automatically Stop)
(Parameter 1) Siren/Strobe Mode: User can change value from 0 to 2 to turn
either Siren sound, Strobe light, or both when triggered.
(Parameter 2) Alarm Auto Stop Time: User can change the duration of siren time
when triggered.
7. Support OTA Firmware update from controller. Please refer to your controller
manual. We recommend to exclude then include the devices from system after
OTA.
8. All the rest commands depend on Z-Wave standard.
Operation
1. Normal operation, the LED light will not on.
2. Alarm Mode:
Active: It will active the Alarm Mode after receiving Basic Set (ON) or Binary
Switch (ON). The LED Strobe Light & SIREN will be active according to the
Configuration’s setting value.
Stop: It will stop the Alarm Mode after receiving Basic Set (OFF) or Binary Switch
(OFF) which depends on Configuration’s setting value.
Auto Stop: After stopping alarm, it will send Binary Switch Report (0x00)
3. Self-Protection Mode: After put back the bracket over 5 seconds, ZM 1601 will
enter the Self-Protection Mode which will active LED Strobe Light & SIREN at the
same time. The Alarm Mode will be triggered If the back cover has been opened
during the Self-Protection Mode If the device is at low battery status, then it will
send Low Voltage Report (COMMAND_CLASS_BATTERY). The Stop method is
same as the Alarm Mode. Open the bracket or close the bracket after 5 seconds will
send notification.
4. Battery Capacity Detection:
* Use “Battery Get” command to have the battery capacity back in % (hexadecimal)
* Auto Battery Capacity Detection
* Low Battery Report at 4.8V (+/- 0.15V)
5. Support Explorer Frame Function
Alarm
Version 1
Notification
Version 4
Alarm Type
0x03
Alarm Level
0x00 (Trigger) /
0xFF (Non Trigger)
Notification Type
0x07
Notification Event
0x03 (Trigger) /
0x00 (Non Trigger)