User's Manual

Introduction
Thanks for choosing the Vision’s wireless 4 in 1 Multi-Sensor (door window contact sensor,
humidity sensor, temperature sensor, and light sensor) of the home security device. This sensor
is a Z-Wave™ enabled device (interoperable, two-way RF mesh networking technology) and is
fully compatible with any Z-Wave™ enabled network and its security framework. Every main
powered Z-Wave enabled device acts as a signal repeater and multiple devices result in more
possible transmission routes which helps eliminate “RF dead-spots”
Z-Wave™ enabled devices displaying the Z-Wave™ logo can also be used with it regardless of
the manufacturer, and ours can also be used in other manufacturer’s Z-Wave™ enabled
networks. This multi-sensor sends Z-Wave™ signal when door or window is opened and closed
or humidity, temperature, luminous change. When the device is secure included into Z-Wave
network, above communication will be encrypted. Security enabled_ Z-Wave controller must be
used to fully utilize the product.
Product Description and Specification
*** For indoor use only***
Specification:
Package
Protocol: Z-Wave™ (ZM5202)
Frequency Range:
865.22MHz (ZD2301IN-5)
868.10MHz (ZD2301MY-5)
868.42MHz (ZD2301EU-5)
869.00MHz (ZD2301RU-5)
908.42MHz (ZD2301US-5)
916.00MHz (ZD2301IL-5)
919~923MHz (ZD2301KR-5)
919.80MHz (ZD2301HK-5)
922~926MHz (ZD2301JP-5)
921.42MHz (ZD2301BR-5)
Operating Range: Up to 100 feet line of sight
Operating Temp.: -15°C~ 60°C (5°F ~140°F)
Battery: CR14250 Battery * 1PC
1pc
1pc
1pc
2pcs
2pcs
1pc
1pc
ZD 2301-5 sensor
Bracket for Magnet
Magnet
Screw to fix magnet
Adhesive tape for Magnet /
sensor
Battery: CR14250 Battery
Installation & Operation manual
Z-Wave Command Classes:
COMMAND_CLASS_ASSOCIATION_GRP_INFO
COMMAND_CLASS_ASSOCIATION_V2
COMMAND_CLASS_BATTERY
COMMAND_CLASS_CONFIGURATION
COMMAND_CLASS_DEVICE_RESET_LOCALLY
COMMAND_CLASS_FIRMWARE_UPDATE_MD_V2
COMMAND_CLASS_MANUFACTURER_SPECIFIC_V2
COMMAND_CLASS_NOTIFICATION_V4
COMMAND_CLASS_POWERLEVEL
COMMAND_CLASS_SECURITY
COMMAND_CLASS_SENSOR_MULTILEVEL_V7
COMMAND_CLASS_VERSION_V2
COMMAND_CLASS_WAKE_UP_V2
COMMAND_CLASS_ZWAVEPLUS_INFO_V2
Notification V4 Type
SWITCH TYPE
STATUS
Notification Type
Reed Switch 0x06
Tamper Switch
0x07
Event
Reed Switch
Close: 0x17, Open: 0x16
Tamper Switch
Close:0x00; Open:0x03
V1 Alarm:
Configuration -Temperature
Parameter
Number
Size VALUE Preset
1 1
°C 0x00 °C(0x00)
°F 0x01
2 1 1~50 (Set up from 0.1°C~5°C)
1 (
°
C)
Switch Type Status
Alarm Type
Reed Switch
0x06
Tamper Switch 0x07
Alarm Level Close: 0x00; Open 0xFF
-1-
-2-