User's Manual

Introduction
Thanks for choosing the Visions wireless door/window sensor of the home security device. This
sensor is a Z-Wave enabled device (interoperable, two-way RF mesh networking technology)
and is fully compatible with any Z-Wave enabled network and its security framework. Every
mains powered Z-Wave enabled device acts as a signal repeater and multiple devices result in
more possible transmission routes which helps eliminate RF dead-spots
Z-Wave™ enabled devices displaying the Z-Wave™ logo can also be used with it regardless of
the manufacturer, and ours can also be used in other manufacturer’s Z-Wave™ enabled
networks. This sensor monitors door/window and send Z-Wave™ signal when door or window
is opened and closed. Recessed Door Sensors are easily installed inside the door or window
frame to keep the sensor hidden from view. When the device is secure included into Z-Wave
network, above communication will be encrypted.
Product Description and Specification
Specification:
Package Content:
Protocol: Z-Wave (ZM5202)
Frequency Range:
865.22MHz (ZD2105IN-5)
868.10MHz (ZD2105MY-5)
868.42MHz (ZD2105EU-5)
869.00MHz (ZD2105RU-5)
908.42MHz (ZD2105US-5)
916.00MHz (ZD2105IL-5)
919~923MHz (ZD2105KR-5)
919.80MHz (ZD2105HK-5)
922~926MHz (ZD2105JP-5)
921.42MHz (ZD2105BR-5)
Operating Range: Up to 100 feet line of sight
Operating Temp.: -15°C~ 60°C (5°F ~140°F)
Battery: CR2 * 1PC
1pc
1pc
1pc
1pc
2pcs
1pc
Z-Wave Command Classes:
COMMAND_CLASS_ASSOCIATION_GRP_INFO
COMMAND_CLASS_ASSOCIATION_V2
COMMAND_CLASS_BATTERY
COMMAND_CLASS_DEVICE_RESET_LOCALLY
COMMAND_CLASS_FIRMWARE_UPDATE_MD_V2
COMMAND_CLASS_MANUFACTURER_SPECIFIC_V2
COMMAND_CLASS_NOTIFICATION_V4 (Mapping COMMAND_CLASS_BASIC)
COMMAND_CLASS_POWERLEVEL
COMMAND_CLASS_SECURITY
COMMAND_CLASS_VERSION_V2
COMMAND_CLASS_WAKE_UP_V2
COMMAND_CLASS_ZWAVEPLUS_INFO_V2
Notification V4 Type
SWITCH
TYPE
STATUS
Notification
Type
Reed Switch
0x06
Tamper
Switch
0x07
Event
Reed Switch
Close: 0x17,
Open: 0x16
Tamper
Switch
Close:0x00;
Open:0x03
V1 Alarm:
Switch Type
Status
Alarm Type
Reed Switch
0x06
Tamper Switch
0x07
Alarm Level
Close: 0x00; Open 0xFF
Installation
Notice: If you are installing the entire Z-Wave™ system for the first time, please refer to
the installation guide of Z-Wave™ Interface Controller before installing ZD2105.
-1-