User's Manual

Notification V4 Type
SWITCH TYPE
STATUS
Notification
Type
Reed Switch
External Switch (When Enable)
0x06
Tamper Switch
0x07
Event
Reed Switch
External Switch (When Enable)
Close: 0x17, Open: 0x16
Tamper Switch
Close:0x00; Open:0x03
Event
Parameter
Reed Switch
External Switch (When Enable)
Close: 0x17, Open: 0x16
Tamper Switch
0x03
V1 Alarm:
Switch Type
Status
Alarm Type
Red Switch &
External Switch
0x06
Tamper Switch
0x07
Alarm Level
Close: 0x00; Open 0xFF
Configuration - External Switch
Parameter Number: 0x01
Size: 1
VALUE
ENABLE
0xFF
DISABLE
(Default)
0x00
Installation
Notice: If you are installing the entire Z-Wave™ system for the first time, please refer to
the installation guide of Z-Wave™ Interface Controller before installing ZD2102.
1. Unscrew the screw fastening the rear cover and slide the rear cover down.
2. Using the screws or adhesive tape to affix the rear cover on the frame along the
opening edge of door / window.
3. Insert a CR123A battery into the battery compartment, LED will start to flash slowly
and ZD2102 will go to sleep if user didnt press the tamper switch within 10 seconds or
ZD2102 will send the NIF.
LED Status for Z-Wave Network:
* After power on, the red LED will flash if the ZD2102 has not been included yet.
* After power on, the red LED will go on if the ZD2102 has been included. (The LED
will turn on lasting 10 seconds then go off and go to sleep mode.)
4. For Inclusion in (adding to) a network: Put the Z-Wave Interface Controller into
inclusion mode, and following its instruction to add the ZD2102 -5 to your controller.
To get in the inclusion mode, the distance between sensor and controller is
suggested to be in one meter. Press the program switch of ZD2102 for sending the
NIF. After sending NIF, Z-Wave will send the auto inclusion; otherwise, ZD2102 will go
to sleep after 15 seconds.
For “Exclusionfrom (removing from) a network: Put the Z-Wave™ Interface
Controller into “exclusion” mode, and following its instruction to delete the ZD2102
from your controller. Press the program switch of ZD2102 for 1 second at least to be
excluded.
Note: All user and network settings will be cleared and the device reset to factory
defaults when the device is excluded.
6. Slide back the rear cover and screw fastening with the front cover, the LED should go
off.
7. Fix the Magnet by using the adhesive tape or fixing screws, locate the Magnet close to
the ZD2102 sensor the distance between these two devices should be in 1.9cm.
8. External Switch: If your window needs two sensors for fully monitoring. You could use
an external switch to connect with the ZD2102 for extending detection. The ZD2102
has 2 normally closed contact terminals. These can be used for additional external
switch wired contacts.
(Remark: Either reed switch or external switch has been opened means open, but,
both of them should be closed at the same time means close.)
9. Awake Mode:
It will be triggering after opening the rear cover, also the red LED will keep on lasting
10 seconds and ZD2102 will send Wake Up Notification after 10 seconds. If ZD2102
received Wake Up No More Information command then the red LED will go off or it
will wait 10 seconds then go off. It will proceed all the commands after sending the
Wake Up Notification
10. Auto Wake Up:
Use “Wake Up” command to set up the awaking time and send the wake up
notification to controller. User can use command to change the auto wake up from
10 minutes to 1 week, Interval increment is 3 minutes.
-3-
-2-
-2-