Datasheet
6FM100P-X
12V 100Ah(10hr)
The rechargeable batteries are lead-lead dioxide systems. The dilute sulfuric acid
electrolyte is absorbed by separators and plates and thus immobilized. Should the
battery be accidentally overcharged producing hydrogen and oxygen, special one-
way valves allow the gases to escape thus avoiding excessive pressure build-up.
Otherwise, the battery is completely sealed and is, therefore, maintenance-free,
leak proof and usable in any position.
Battery Construction
Component Positive plate Negative plate Container Cover Safety valve Terminal Separator Electrolyte
Raw material Lead dioxide Lead ABS ABS Rubber Copper Fiberglass Sulfuric acid
General Features
●
Advanced pure lead technology.
●
Stronger discharge performance.
Excellent consistency and reliability.
●
Special design to avoid thermal runaway.
●
Can be mounted in any orientation.
●
Longer float & cycle life, longer warranty.
●
Maintenance-free operation.
●
Low self discharge.
Dimensions and Weight
page1 of 2
www.vision-batt.com
Length(mm / inch) 339 / 13.35
Width(mm / inch) 173 / 6.81
Height(mm / inch) 214.5 / 8.44
Total Height(mm / inch) 220 / 8.66
Approx. Weight(Kg / lbs) 27.5 / 60.6
Performance Characteristics
Nominal Voltage 12V
Number of cell 6
Nominal Capacity 77
o
F(25
o
C)
10 hour rate (10.0A, 10.8V) 100Ah
5 hour rate (17.5A, 10.5V) 87.5 .Ah
1 hour rate (66.2A, 9.6V) 66.2Ah
Internal Resistance
Fully Charged battery 77
o
F(25
o
C)
5.7mOhms
Self-Discharge
3% of capacity declined per month at 20
o
C(average)
Operating Temperature Range
Discharge
-20~60
o
C
Charge
-10~60
o
C
Storage
-20~60
o
C
Max. Discharge Current 77
o
F(25
o
C)
900A(5s)
Short Circuit Current 2500A
Charge Methods: Constant Voltage Charge 77
o
F(25
o
C)
Cycle use
Maximum charging current 30A
Temperature compensation
-30mV/
o
C
Standby use
Temperature compensation
-20mV/
o
C
Discharge Constant Current (Amperes at 77
o
F25
o
C)
Discharge Constant Power (Watts at 77
o
F25
o
C)
(Note)The above characteristics data are average values obtained within
three charge/discharge cycles not the mimimum values.
EndPoint
Volts/Cell
10min 15min 30min 1h 3h 5h 10h 20h
1.60V 229 185 108 66.2 27.9 19.0 10.8 5.50
1.65V 221 178 104 62.5 27.7 18.3 10.6 5.45
1.70V 200 164 96.0 61.5 27.2 18.0 10.5 5.40
1.75V 187 153 93.0 60.5 26.9 17.5 10.3 5.35
1.80V 175 143 91.0 57.4 25.3 17.2 10.0 5.30
EndPoint
Volts/Cell
10min 15min 30min 45min 1h
10h
3h 5h
1.60V 392 321 199 150 124
20.3
52.8 35.8
1.65V 379 315 188 146 118
20.1
51.2 35.4
1.70V 360 299 183 137 114
20.0
50.9 35.0
1.75V 353 294 177 134 111
19.6
49.1 34.4
1.80V 329 279 171 131 104
19.1
48.5 34.0
2.40-2.45VPC
2.20-2.30VPC
≤
5min
314
296
270
242
221
5min
547
517
478
441
415
Design Life 10 years
●
339±1
173±1
214.5±1
220±1
44
266
16
M8
5
●
Case and cover avaiable in both standard
and flame restardant ABS.
Weight deviation: ± 3%
*