Data Sheet
6FM100D-X
Charge characteristic curve
Charging time (hours)
Charged
Volume
(%)
Current
(XCA)
Voltage
(V)
15.0
14.0
13.0
12.0
11.0
0.25
0.20
0.15
0.10
0.05
0
0 2 4 6 8 10 12 14 16 18 20
Constant voltage charge characteristic
o
(0.25CA,25 C)
CHARGED VOLUME
140
120
100
80
60
40
20
0
CHARGE VOLTAGE
CHARGING CURRENT
Self-discharge characteristic
110
100
90
80
70
60
50
40
0 2 4 6 8 10 12 14 16 18 20
Storage time: months
Capacity(%)
o
40 C
o
30 C
o
20 C
Relationship between
charging voltage and temperature
-10 0 10 20 30 40 50 60
o
Ambient temperature( C)
(V/12V)
15.6
15.0
14.4
13.8
13.2
(V/8V)
(V/6V)
(V/4V)
(V/CELL)
10.4
10.0
9.6
9.2
8.8
7.8
7.5
7.2
6.9
6.6
5.2
5.0
4.8
4.6
4.4
2.6
2.5
2.4
2.3
2.2
STA BY USND E
CYCLE USE
Life characteristics of standby use
Capacity(%)
120
100
80
60
40
20
0
0 4 6 8
Life(year)
Testing conditions: floating voltage: 2.27 to 2.30V/Cell
oo
ambient temperature: 25 C(77 F)
Cycle service life in relation to
depth of discharge
Number of cycles(cycles)
Capacity(%)
120
100
80
60
40
20
0
200 400 600 800 1000 1200 1400 1600
100% D.O.D. 50% D.O.D.
30% Depth of discharge
Temperature effects on float life
15
10
5
0
Life(years)
o
Temperature( C)
10 20 30 40 50
2.30V/Cell
Temperature effects on capacity
120
100
80
60
40
20
0
-20 -10 0 10 20 30 40 50
Capacity (%)
o
Temperature( C)
0.1C
0.2C
01. C
2 0. C
C0.05
Page 2 of 2
1
3
5 10 20
30
60
2
3
5 10 20
O
Discharge characteristic (25 C)
2
min
h
Discharge time
Battery voltage(V)
12.0
9.6
0
10A
17.5A
24.7A
64.5A
90A
185A
12V 100 Ah
Powered for Solar Applications