Data Sheet
6FM100D-X
The rechargeable batteries are lead-lead dioxide systems. The dilute sulfuric acid
electrolyte is absorbed by separators and plates and thus immobilized. Should the
battery be accidentally overcharged producing hydrogen and oxygen, special one-
way valves allow the gases to escape thus avoiding excessive pressure build-up.
Otherwise, the battery is completely sealed and is, therefore, maintenance-free,
leak proof and usable in any position.
Battery Construction
Component Positive plate Negative plate Container Cover Safety valve Terminal Separator Electrolyte
Raw material Lead dioxide Lead ABS ABS Rubber Copper Fiberglass Sulfuric acid
General Features
●
Absorbent Glass Mat (AGM) technology
for efficient gas recombination of up to
99% and freedom from electrolyte
maintenance or water adding.
●
Not restricted for air transport-complies
with IATA/ICAO Special Provision A67.
●
UL-recognized component.
●
Can be mounted in any orientation.
●
Computer designed lead, calcium tin alloy
grid for high power density.
●
Long service life, float or cyclic
applications.
●
Maintenance-free operation.
●
Low self discharge.
Dimensions and Weight
Length(mm / inch) 330 / 12.99
Width(mm / inch) 171 / 6.73
Height(mm / inch) 215 / 8.46
Total Height(mm / inch) 220 / 8.66
Approx. Weight(Kg / lbs) 32 / 70.5
Performance Characteristics
Nominal Voltage 12V
Number of cell 6
Design Life 10 years
Nominal Capacity 77
o
F(25
o
C)
Internal Resistance
Fully Charged battery 77
o
F(25
o
C)
5mOhms
Self-Discharge
3% of capacity declined per month at 20
o
C(average)
Operating Temperature Range
Discharge
-20~60
o
C
Charge
-10~60
o
C
Storage
-20~60
o
C
Max. Discharge Current 77
o
F(25
o
C)
900A(5s)
Short Circuit Current 2100A
Charge Methods: Constant Voltage Charge 77
o
F(25
o
C)
Cycle use 14.4-14.7V
Maximum charging current 30A
Temperature compensation
-30mV/
o
C
Standby use 13.6-13.8V
Temperature compensation
-20mV/
o
C
Discharge Constant Current (Amperes at 77
o
F25
o
C)
Discharge Constant Power (Watts at 77
o
F25
o
C)
page1 of 2
www.vision-batt.com
(Note)The above characteristics data are average values obtained within
three charge/discharge cycles not the mimimum values.
End Point
Volts/ce
l
l
5min 10min 15min 30min 1h 3h 5h 10h 20h 100h
1.60V 328 224 185 105 64.5 26.4 18.4 10.4 5.39 1.20
1.65V 301 210 176 101 64.1 25.9 18.1 10.3 5.34 1.19
1.70V 274 195 166 97.5 64.4 25.3 17.9 10.3 5.28 1.18
1.75V 246 182 155 94.5 62.4 24.7 17.5 10.2 5.24 1.17
1.80V 218 166 146 92.5 60.4 24.0 17.2 10.0 5.03 1.16
End Point
Volts/ce
l
l
5min 10min 15min 30min 45min 1h 2h 3h 5h 100h
1.60V 564 398 325 197 147 126 71.7 51.4 35.6 2.41
1.65V 525 378 320 191 142 124 70.6 50.9 35.4 2.41
1.70V 486 358 310 186 139 123 69.2 50.3 35.1 2.40
1.75V 448 339 298 180 136 118 68.0 49.7 34.9 2.39
1.80V 407 317 288 174 133 116 67.3 49.1 34.6 2.39
12V 120 Ah (100 hr)
Powered for Solar Applications
100 hour rate (1.2A, 9.6V) 120.0Ah
10 hour rate (10.0A, 10.8V) 100.0Ah
5 hour rate (16.7A, 10.5V) 83.5Ah