IGBT ELECTRICAL SPECIFICATIONS (T
C
= 25 °C unless otherwise noted)
PARAMETER SYMBOL TEST CONDITIONS MIN. TYP. MAX. UNITS
Collector to emitter breakdown voltage V
(BR)CES
T
J
= 25 °C 600 - -
VCollector to emitter saturation voltage V
CE(sat)
V
GE
= 15 V, I
C
= 100 A, T
J
= 25 °C - 1.65 2.10
V
GE
= 15 V, I
C
= 100 A, T
J
= 175 °C - 2.00 -
Gate to emitter threshold voltage V
GE(th)
V
CE
= V
GE
, I
C
= 1.0 mA, T
J
= 25 °C 4.0 4.4 6.5
Collector cut-off current I
CES
V
CE
= V
CES
, V
GE
= 0 V, T
J
= 25 °C - - 5.0 mA
Gate to emitter leakage current I
GES
V
GE
= V
GES
, V
CE
= 0 V, T
J
= 25 °C - - 400 nA
SWITCHING CHARACTERISTICS
PARAMETER SYMBOL TEST CONDITIONS MIN. TYP. MAX. UNITS
Turn-on delay time t
d(on)
V
CC
= 300 V, I
C
= 100 A, R
g
= 2.2 ,
V
GE
= ± 15 V, T
J
= 25 °C
- 106 -
ns
Rise time t
r
-49-
Turn-off delay time t
d(off)
- 102 -
Fall time t
f
-85-
Turn-on switching loss E
on
-0.46-
mJ
Turn-off switching loss E
off
-0.95-
Turn-on delay time t
d(on)
V
CC
= 300 V, I
C
= 100 A, R
g
= 2.2 ,
V
GE
= ± 15 V, T
J
= 125 °C
- 112 -
ns
Rise time t
r
-62-
Turn-off delay time t
d(off)
- 126 -
Fall time t
f
- 109 -
Turn-on switching loss E
on
-0.78-
mJ
Turn-off switching loss E
off
-1.73-
Input capacitance C
ies
V
GE
= 0 V, V
CE
= 30 V, f = 1.0 MHz
-7.71-
nFOutput capacitance C
oes
-0.53-
Reverse transfer capacitance C
res
-0.23-
SC data I
SC
t
p
5 μs, V
GE
= 15 V, T
J
= 125 °C,
V
CC
= 360 V, V
CEM
1200 V
- 900 - A
Stray inductance L
CE
- - 30 nH
Module lead resistance, terminal to chip R
CC’+EE’
-0.75- m
DIODE ELECTRICAL SPECIFICATIONS (T
C
= 25 °C unless otherwise noted)
PARAMETER SYMBOL TEST CONDITIONS MIN. TYP. MAX. UNITS
Forward voltage V
F
I
F
= 100 A
T
J
= 25 °C - 1.40 1.80
V
T
J
= 125 °C - 1.40 -
Reverse recovery charge Q
rr
I
F
= 100 A, V
R
= 600 V,
R
G
= 5.6
V
GE
= - 15 V
T
J
= 25 °C - 5.5 -
μC
T
J
= 125 °C - 7.3 -
Peak reverse recovery current I
rr
T
J
= 25 °C - 68 -
A
T
J
= 125 °C - 88 -
Reverse recovery energy E
rec
T
J
= 25 °C - 0.89 -
mJ
T
J
= 125 °C - 1.71 -