Datasheet
www.vishay.com For technical questions, contact: diodestech@vishay.com
Document Number: 94029
4 Revision: 11-Mar-10
VS-8ETL06SPbF, VS-8ETL06-1PbF
Vishay High Power Products
Ultralow V
F
Hyperfast Rectifier for
Discontinuous Mode PFC, 8 A FRED Pt
®
Fig. 5 - Maximum Allowable Case Temperature vs.
Average Forward Current
Fig. 6 - Forward Power Loss Characteristics
Fig. 7 - Typical Reverse Recovery Time vs. dI
F
/dt
Fig. 8 - Typical Stored Charge vs. dI
F
/dt
Note
(1)
Formula used: T
C
= T
J
- (Pd + Pd
REV
) x R
thJC
;
Pd = Forward power loss = I
F(AV)
x V
FM
at (I
F(AV)
/D) (see fig. 6);
Pd
REV
= Inverse power loss = V
R1
x I
R
(1 - D); I
R
at V
R1
= Rated V
R
02 6 10 14
Allowable Case Temperature (°C)
I
F(AV)
- Average Forward Current (A)
150
160
48
165
170
175
180
155
Square wave (D = 0.50)
Rated V
R
applied
See note (1)
DC
12
02 6 1012
Average Power Loss (W)
I
F(AV)
- Average Forward Current (A)
0
4
D = 0.01
D = 0.02
D = 0.05
D = 0.10
D = 0.20
D = 0.50
DC
RMS limit
48
8
12
10
6
2
100 1000
t
rr
(ns)
dI
F
/dt (A/µs)
450
0
I
F
= 16 A
I
F
= 8 A
V
R
= 390 V
T
J
= 125 °C
T
J
= 25 °C
400
300
200
100
50
150
250
350
100 1000
Q
rr
(nC)
dI
F
/dt (A/µs)
1000
4000
3000
2000
1500
5000
3500
2500
4500
I
F
= 16 A
I
F
= 8 A
500
V
R
= 390 V
T
J
= 125 °C
T
J
= 25 °C