Brochure
5
The peak voltage graphs above, as a function of the resistance value, show the pulsed high voltage capability for each
VR resistor size, with capability up to 7kV for the VR25 and 10kV for VR37 and VR68, in accordance with IEC 60065
standard, clause 14.2, for a 1nF capacitor discharge test.
HIGH VOLTAGE FEATURES
Maximum allowed peak pulse voltage in
accordance with IEC 60065, 14.2
50 discharges from a 1nF capacitor
charged to Ûmax; 12 discharges/min
(drift dR/R ≤ 2 %)