Note
Test conditions per JIS C5101-1
POWER DISSIPATION
CASE CODE MAXIMUM PERMISSIBLE POWER DISSIPATION AT +25 °C (W) IN FREE AIR
P 0.064
STANDARD PACKAGING QUANTITY
CASE CODE UNITS PER 7" REEL
P 3000
PERFORMANCE CHARACTERISTICS
ITEM CONDITION POST TEST PERFORMANCE
Temperature
characteristics
Measure the specified characteristics in
each stage
Specified
initial value
-55 °C +85 °C +125 °C
Capacitance
change
- -20 % to 0 % 0 % to +20 % 0 % to +20 %
Dissipation
factor (%)
610 8 10
812 10 12
10 14 12 14
12 16 14 16
20 24 22 24
30 60 30 40
Leakage
current
Refer to
Standard
Ratings
table
-
1000 %
specified
intial value
or less
1250 %
specified
intial value
or less
Solder heat
resistance
Solder dip:
260 °C ± 5 °C 10 s ± 1 s
Reflow:
260 °C 10 s ± 1 s
Capacitance change Within ± 20 % of initial value
Dissipation factor Initial specified value or less
Leakage current Initial specified value or less
Moisture
resistance
no load
Leave at 40 °C and
90 % to 95 % RH for 500 h
Capacitance change Within ± 20 % of initial value
Dissipation factor Shall not exceed 150 % of initial specified value
Leakage current Initial specified value or less
High
temperature
load
85 °C. The rated voltage is applied for
2000 h
Capacitance change Within ± 20 % of initial value
Dissipation factor Initial specified value or less
Leakage current Shall not exceed 200 % of initial specified value
Thermal shock
Leave at -55 °C, normal temperature,
125 °C, and normal temperature for
30 min, 3 min, 30 min, and 3 min.
Repeat this operation 5 times running
Capacitance change Within ± 20 % of initial value
Dissipation factor Initial specified value or less
Leakage current Initial specified value or less
Moisture
resistance
load
Leave at 40 °C and 90 % to 95 % RH
The rated voltage is applied for 500 h
Capacitance change Within ± 20 % of initial value or less
Dissipation factor Shall not exceed 150 % of initial specified value
Leakage current Shall not exceed 200 % of initial specified value
Failure rate
85 °C. The rated voltage is applied
through a protective resistor of 1 /V.
1 % / 1000 h