Datasheet

TCLT10.. Series
Document Number 83515
Rev. 2.0, 27-Sep-05
Vishay Semiconductors
www.vishay.com
3
Coupler
Current Transfer Ratio
Maximum Safety Ratings
(according to DIN EN 60747-5-2(VDE0884)/ DIN EN 60747-5-5 pending) see figure 1
This optocoupler is suitable for safe electrical isolation only within the safety ratings.
Compliance with the safety ratings shall be ensured by means of suitable protective circuits.
Input
Output
Coupler
Parameter Test condition Symbol Min Typ. Max Unit
Collector emitter saturation
voltage
I
F
= 10 mA, I
C
= 1 mA V
CEsat
0.3 V
Cut-off frequency V
CE
= 5 V, I
F
= 10 mA,
R
L
= 100
f
c
110 kHz
Coupling capacitance f = 1 MHz C
k
0.3 pF
Parameter Test condition Part Symbol Min Ty p. Max Unit
I
C
/I
F
V
CE
= 5 V, I
F
= 5 mA TCLT1000 CTR 50 600 %
V
CE
= 5 V, I
F
= 10 mA TCLT1002 CTR 63 125 %
TCLT1003 CTR 100 200 %
V
CE
= 5 V, I
F
= 1 mA TCLT1002 CTR 22 45 %
TCLT1003 CTR 34 70 %
TCLT1004 CTR 56 100 %
V
CE
= 5 V, I
F
= 5 mA TCLT1005 CTR 50 150 %
TCLT1006 CTR 100 300 %
TCLT1007 CTR 80 160 %
TCLT1008 CTR 130 260 %
TCLT1009 CTR 200 400 %
Parameter Test condition Symbol Min Typ. Max Unit
Forward current I
F
130 mA
Parameter Test condition Symbol Min Typ. Max Unit
Power dissipation P
diss
265 mW
Parameter Test condition Symbol Min Typ. Max Unit
Rated impulse voltage V
IOTM
8kV
Safety temperature T
si
150 °C