Datasheet

Document Number: 62752
S12-1763-Rev. A, 23-Jul-12
www.vishay.com
3
Vishay Siliconix
Si8489EDB
This document is subject to change without notice.
THE PRODUCTS DESCRIBED HEREIN AND THIS DOCUMENT ARE SUBJECT TO SPECIFIC DISCLAIMERS, SET FORTH AT www.vishay.com/doc?91000
For technical questions, contact: pmostechsupport@vishay.com
Notes:
a. Pulse test; pulse width 300 µs, duty cycle 2 %.
b. Guaranteed by design, not subject to production testing.
Stresses beyond those listed under “Absolute Maximum Ratings” may cause permanent damage to the device. These are stress ratings only, and functional operation
of the device at these or any other conditions beyond those indicated in the operational sections of the specifications is not implied. Exposure to absolute maximum
rating conditions for extended periods may affect device reliability.
TYPICAL CHARACTERISTICS (25 °C, unless otherwise noted)
SPECIFICATIONS (T
J
= 25 °C, unless otherwise noted)
Parameter Symbol Test Conditions Min. Typ. Max. Unit
Drain-Source Body Diode Characteristics
Continuous Source-Drain Diode Current
I
S
T
A
= 25 °C
- 1.5
A
Pulse Diode Forward Current
I
SM
- 20
Body Diode Voltage
V
SD
I
S
= - 1.5 A, V
GS
= 0 V
- 0.8 - 1.2 V
Body Diode Reverse Recovery Time
t
rr
I
F
= - 1.5 A, dI/dt = 100 A/µs, T
J
= 25 °C
25 50 ns
Body Diode Reverse Recovery Charge
Q
rr
920nC
Reverse Recovery Fall Time
t
a
15
ns
Reverse Recovery Rise Time
t
b
10
Gate Current vs. Gate-Source Voltage
Output Characteristics
0
10
20
30
40
50
60
0 3 6 9 12 15 18
I
GSS
- Gate Current (mA)
V
GS
- Gate-Source Voltage (V)
T
J
= 25 °C
0
4
8
12
16
20
0.0 0.5 1.0 1.5 2.0 2.5 3.0
I
D
- Drain Current (A)
V
DS
- Drain-to-Source Voltage (V)
V
GS
= 2 V
V
GS
= 2.5 V
V
GS
= 5 V thru 3 V
V
GS
= 1.5 V
Gate Current vs. Gate-Source Voltage
Transfer Characteristics
10
-2
10
-3
10
-4
10
-5
10
-6
10
-7
10
-8
10
-9
0 3 6 9 12 15 18
I
GSS
- Gate Current (A)
V
GS
- Gate-to-Source Voltage (V)
T
J
= 150 °C
T
J
= 25 °C
0
4
8
12
16
20
0.0 0.5 1.0 1.5 2.0 2.5 3.0
I
D
- Drain Current (A)
V
GS
- Gate-to-Source Voltage (V)
T
C
= 25 °C
T
C
= 125 °C
T