Datasheet
www.vishay.com
2
Document Number: 68932
S-82616-Rev. B, 03-Nov-08
Vishay Siliconix
Si7114ADN
Notes:
a. Pulse test; pulse width ≤ 300 µs, duty cycle ≤ 2 %.
b. Guaranteed by design, not subject to production testing.
Stresses beyond those listed under “Absolute Maximum Ratings” may cause permanent damage to the device. These are stress ratings only, and functional operation
of the device at these or any other conditions beyond those indicated in the operational sections of the specifications is not implied. Exposure to absolute maximum
rating conditions for extended periods may affect device reliability.
SPECIFICATIONS T
J
= 25 °C, unless otherwise noted
Parameter Symbol Test Conditions Min. Typ. Max. Unit
Static
Drain-Source Breakdown Voltage
V
DS
V
GS
= 0 V, I
D
= 250 µA
30 V
V
DS
Temperature Coefficient
ΔV
DS
/T
J
I
D
= 250 µA
33
mV/°C
V
GS(th)
Temperature Coefficient
ΔV
GS(th)
/T
J
- 6
Gate-Source Threshold Voltage
V
GS(th)
V
DS
= V
GS
, I
D
= 250 µA
1.2 2.5 V
Gate-Source Leakage
I
GSS
V
DS
= 0 V, V
GS
= ± 20 V
± 100 nA
Zero Gate Voltage Drain Current
I
DSS
V
DS
= 30 V, V
GS
= 0 V
1
µA
V
DS
= 30 V, V
GS
= 0 V, T
J
= 55 °C
5
Drain-Source On-State Resistance
a
R
DS(on)
V
GS
= 10 V, I
D
= 18 A
0.0062 0.0075
Ω
V
GS
= 4.5 V, I
D
= 16 A
0.0081 0.0098
Forward Transconductance
a
g
fs
V
DS
= 15 V, I
D
= 18 A
50 S
Dynamic
b
Input Capacitance
C
iss
V
DS
= 15 V, V
GS
= 0 V, f = 1 MHz
1230
pFOutput Capacitance
C
oss
275
Reverse Transfer Capacitance
C
rss
105
Total Gate Charge
Q
g
V
DS
= 15 V, V
GS
= 10 V, I
D
= 19 A
21 32
nC
V
DS
= 15 V, V
GS
= 4.5 V, I
D
= 19 A
10.2 20
Gate-Source Charge
Q
gs
3.9
Gate-Drain Charge
Q
gd
3.2
Gate Resistance
R
g
f = 1 MHz 0.3 1.6 3.2 Ω
Tur n - O n D e l ay Time
t
d(on)
V
DD
= 15 V, R
L
= 1.5 Ω
I
D
≅ 10 A, V
GEN
= 4.5 V, R
g
= 1 Ω
20 30
ns
Rise Time
t
r
14 21
Turn-Off Delay Time
t
d(off)
20 30
Fall Time
t
f
10 20
Tur n - O n D e l ay T im e
t
d(on)
V
DD
= 15 V, R
L
= 1.5 Ω
I
D
≅ 10 A, V
GEN
= 10 V, R
g
= 1 Ω
11 20
Rise Time
t
r
816
Turn-Off Delay Time
t
d(off)
20 30
Fall Time
t
f
714
Drain-Source Body Diode Characteristics
Continuous Source-Drain Diode Current
I
S
T
C
= 25 °C
32
A
Pulse Diode Forward Current
I
SM
60
Body Diode Voltage
V
SD
I
S
= 10 A, V
GS
= 0 V
0.8 1.2 V
Body Diode Reverse Recovery Time
t
rr
I
F
= 10 A, dI/dt = 100 A/µs, T
J
= 25 °C
24 36 ns
Body Diode Reverse Recovery Charge
Q
rr
20 30 nC
Reverse Recovery Fall Time
t
a
16
ns
Reverse Recovery Rise Time
t
b
8