Fig. 1 - Switching Operation (without Saturation) Fig. 2 - Switching Operation (with Saturation)
Note
As per IEC 60747-5-2, § 7.4.3.8.1, this optocoupler is suitable for “safe electrical insulation” only within the safety ratings. Compliance with
the safety ratings shall be ensured by means of protective circuits.
SWITCHING CHARACTERISTICS (T
amb
= 25 °C, unless otherwise specified)
PARAMETER TEST CONDITION SYMBOL MIN. TYP. MAX. UNIT
NON-SATURATED
Rise time I
C
= 2 mA, V
CC
= 10 V, R
L
= 100 t
r
s
Fall time I
C
= 2 mA, V
CC
= 10 V, R
L
= 100 t
f
s
Turn-on time I
C
= 2 mA, V
CC
= 10 V, R
L
= 100 t
on
s
Turn-off time I
C
= 2 mA, V
CC
= 10 V, R
L
= 100 t
off
s
SATURATED
Rise time I
F
= 16 mA, V
CC
= 5 V, R
L
= 1.9 k t
r
15 μs
Fall time I
F
= 16 mA, V
CC
= 5 V, R
L
= 1.9 k t
f
0.5 μs
Turn-on time I
F
= 16 mA, V
CC
= 5 V, R
L
= 1.9 k t
on
s
Turn-off time I
F
= 16 mA, V
CC
= 5 V, R
L
= 1.9 k t
off
30 μs
isfh6916_01
R
L
= 100 Ω
V
CC
= 10 V
I
C
50 Ω
I
F
isfh6916_02
R
L
= 1.9 kΩ
V
CC
=5V
I
C
50 Ω
I
F
SAFETY AND INSULATION RATINGS
PARAMETER TEST CONDITION SYMBOL MIN. TYP. MAX. UNIT
Climatic classification
(according to IEC 68 part 1)
55/100/21
Comparative tracking index CTI 175 399
Peak transient overvoltage V
IOTM
6000 V
Peak insulation voltage V
IORM
707 V
Safety rating - power output P
SO
350 mW
Safety rating - input current I
SI
150 mA
Safety rating - temperature T
SI
175 °C
Creepage distance 5 mm
Clearance distance 5 mm