Datasheet

2381 66. 5...1/PTCCL..H....BE
Vishay BCcomponents
Document Number: 29085 For technical questions, contact: nlr@vishay.com
www.vishay.com
Revision: 29-Jul-09 15
30 V to 60 V PTC Thermistors
For Overload Protection
FEATURES
Wide range of trip and non-trip currents:
From 94 mA up to 2 A for the trip current
Small ratio between trip and non-trip currents
(I
t
/I
nt
= 1.5 at 25 °C)
High maximum overload current (up to 23 A)
Leaded parts withstand mechanical stresses
and vibration
UL file E148885 according to XGPU standard UL1434
UL approved PTCs are guaranteed to withstand severe
test programs
Long-life cycle tests (over 5000 trip cycles)
Long-life storage tests (3000 h at 250 °C)
Electrical cycle tests at low ambient temperatures
(- 40 °C or 0 °C)
Damp-heat and water immersion tests
Overvoltage tests at up to 200 % of rated voltage
Compliant to RoHS directive 2002/95/EC and in
accordance to WEEE 2002/96/EC
APPLICATIONS
Over-temperature/over-load protection:
Telecommunications
Automotive systems
Industrial electronics
Consumer electronics
Electronic data processing
DESCRIPTION
These directly heated thermistors have a positive
temperature coefficient and are primarily intended for
overload protection. They consist of a naked disk with two
tinned brass or copper clad steel leads and are coated with
a high temperature silicone UL 94 V-0 coating. Leadless
disks and leaded disks without coating are available on
request.
MOUNTING
The PTC Thermistors are suitable for processing on
automatic insertion equipment.
Typical soldering
235 °C; duration: 5 s (Pb-bearing)
245 °C, duration: 5 s (Lead (Pb)-free)
Resistance to soldering heat
260 °C, duration: 10 s max.
MARKING
Only the grey lacquered thermistors with a diameter of
8.5 mm to 20.5 mm are marked with BC, R
25
value (example
1R9) on one side and I
nt
, V
max.
on the other side.
QUICK REFERENCE DATA
PARAMETER VALUE UNIT
Maximum voltage (DC or AC) 30 to 60 V
Holding current 0.094 to 2 A
Resistance at 25 °C (R
25
) 0.3 to 50 Ω
I
max.
0.8 to 23 A
Switch temperature 140 °C
Operating temperature range
at max. voltage
- 40 to + 85 °C
Climatic category 40/125/56

Summary of content (6 pages)