Datasheet

MMU 0102, MMA 0204, MMB 0207 - Professional
www.vishay.com
Vishay Beyschlag
Revision: 09-Feb-16
2
Document Number: 28713
For technical questions, contact: melf@vishay.com
THIS DOCUMENT IS SUBJECT TO CHANGE WITHOUT NOTICE. THE PRODUCTS DESCRIBED HEREIN AND THIS DOCUMENT
ARE SUBJECT TO SPECIFIC DISCLAIMERS, SET FORTH AT www.vishay.com/doc?91000
Note
The presented operation modes do not refer to different types of resistors, but actually show examples of different loads, that lead to
different film temperatures and different achievable load-life stability (drift) of the resistance value. A suitable low thermal resistance of the
circuit board assembly must be safeguarded in order to maintain the film temperature of the resistors within the specified limits. Please
consider the application note “Thermal Management in Surface-Mounted Resistor Applications” (www.vishay.com/doc?28844
) for
information on the general nature of thermal resistance.
MAXIMUM RESISTANCE CHANGE AT RATED DISSIPATION
OPERATION MODE STANDARD POWER
Rated dissipation, P
70
MMU 0102 0.2 W 0.3 W
MMA 0204 0.25 W 0.4 W
MMB 0207 0.4 W 1.0 W
Operating temperature range -55 °C to 125 °C -55 °C to 155 °C
Permissible film temperature,
F
max. 125 °C 155 °C
Max. resistance change at P
70
for
resistance range, |R/R| after:
MMU 0102 0.22 to 221 k 0.22 to 221 k
MMA 0204 0.22 to 332 k 0.22 to 332 k
MMB 0207 0.1 to 1 M 0.1 to 1 M
1000 h 0.15 % 0.25 %
8000 h 0.3 % 0.5 %
225 000 h 1.0 % -
TEMPERATURE COEFFICIENT AND RESISTANCE RANGE
TYPE/SIZE TCR TOLERANCE RESISTANCE E-SERIES
MMU 0102
± 50 ppm/K
± 5 % 0.22 to 0.91
E24
± 2 % 1 to 9.1
± 1 % 10 to 2.21 M E24; E96
± 0.5 % 10 to 221 k E24; E192
± 25 ppm/K
± 1 % 10 to 221 k E24; E96
± 0.5 % 10 to 221 k E24; E192
Jumper; I
max.
= 2 A 10 m 0 -
MMA 0204
± 50 ppm/K
± 5 % 0.22 to 0.91 E24
± 1 % 1 to 10 M E24; E96
± 0.5 % 10 to 2.21 M E24; E192
± 25 ppm/K
± 1 % 10 to 511 k E24; E96
± 0.5 % 10 to 511 k E24; E192
Jumper; I
max.
= 3 A 10 m 0 -
MMB 0207
± 100 ppm/K ± 5 % 0.1 to 0.2
E24
± 50 ppm/K
± 5 % 0.22 to 0.91
± 2 % 0.22 to 0.91
± 1 % 1 to 15 M E24; E96
± 25 ppm/K ± 0.5 % 10 to 1 M E24; E192
Jumper; I
max.
= 5 A 10 m 0 -