Datasheet

196 DLC
www.vishay.com
Vishay BCcomponents
Revision: 13-Mar-18
6
Document Number: 28362
For technical questions, contact: energystorage@vishay.com
THIS DOCUMENT IS SUBJECT TO CHANGE WITHOUT NOTICE. THE PRODUCTS DESCRIBED HEREIN AND THIS DOCUMENT
ARE SUBJECT TO SPECIFIC DISCLAIMERS, SET FORTH AT www.vishay.com/doc?91000
Table 2
Statements about product lifetime are based on calculations and internal testing. They should only be interpreted as estimations. Also due to external factors, the
lifetime in the field application may deviate from the calculated lifetime. In general, nothing stated herein shall be construed as a guarantee of durability.
TEST PROCEDURES AND REQUIREMENTS for standard and vertical miniaturized series (5.5 V; 70 °C)
NAME OF TEST
IEC 60384-4 /
EN130300
SUBCLAUSE
PROCEDURE
(quick reference)
REQUIREMENTS
Robustness of
terminations
4.4
Tensile strength; application of loading force for 10 s:
No breaks20 N (standard series)
5 N (vertical miniaturized series)
Resistance to
soldering heat
4.5 Solder bath; 260 °C; 5 s
C/C: ± 10 %
R
I
and I
L
spec. limit
Solderability 4.6 Solder bath; 235 °C; 2 s 75 % tinning
Vibration 4.8
10 Hz to 55 Hz; 1.5 mm; 3 directions;
2 h per direction
C/C: ± 10 %
R
I
and I
L
spec. limit
Damp heat,
steady state
4.12
500 h at 55 °C; RH 90 % to 95 %;
no voltage applied
C/C: ± 30 %
R
I
4 x spec. limit
I
L
2 x spec. limit
Endurance 4.13
T
amb
= 70 °C; 5.5 V applied;
1000 h
C/C: ± 30 %
R
I
4 x spec. limit
I
L
2 x spec. limit
Useful life -
T
amb
= 70 °C; 5.5 V applied;
1000 h
C/C: ± 30 %
R
I
4 x spec. limit
I
L
2 x spec. limit
Storage at upper
category temperature
4.17
T
amb
= 70 °C;
no voltage applied;
1000 h
C/C: ± 30 %
R
I
4 x spec. limit
I
L
2 x spec. limit
Self discharge -
24 h storage at room temperature after application
of 5 V for 1 h
Remaining voltage: 4 V
Characteristics at high
and low temperature
4.19
Step 1: reference measurement
at +20 °C of C, R
I
and I
L
Step 2: measurement at -25 °C
Step 3: measurement at +20 °C
Step 4: measurement at +70 °C
Step 5: measurement at +20 °C
C/C: ± 30 % of +20 °C value
R
I
5 x the +20 °C value
I
L
4 x the +20 °C value