Datasheet
051/053 PEC-PW
www.vishay.com
Vishay BCcomponents
Revision: 17-Feb-12
9
Document Number: 28346
For technical questions, contact: aluminumcaps2@vishay.com
THIS DOCUMENT IS SUBJECT TO CHANGE WITHOUT NOTICE. THE PRODUCTS DESCRIBED HEREIN AND THIS DOCUMENT
ARE SUBJECT TO SPECIFIC DISCLAIMERS, SET FORTH AT www.vishay.com/doc?91000
RIPPLE CURRENT AND USEFUL LIFE
Fig. 24 - Multiplier of useful life as a function of ambient temperature and ripple current load
Table 4
Table 5
MULTIPLIER OF RIPPLE CURRENT (I
R
) AS A FUNCTION OF FREQUENCY
FREQUENCY (Hz) I
R
MULTIPLIER
50 0.83
100 1.00
200 1.10
400 1.15
1000 1.19
2000 1.20
TEST PROCEDURES AND REQUIREMENTS
TEST
PROCEDURE
(quick reference)
REQUIREMENTS
NAME OF TEST REFERENCE
Endurance
IEC 60384-4/
EN130300
subclause 4.13
T
amb
= 85 °C; U
R
applied;
5000 h
U
R
100 V; C/C: ± 15 %
U
R
100 V; C/C: ± 10 %
ESR 1.3 x spec. limit
Z 2 x spec. limit
I
L5
spec. limit
Useful life
CECC 30301
subclause 1.8.1
T
amb
= 85 °C; U
R
and I
R
applied;
12 000 h
U
R
100 V; C/C: ± 45 %
U
R
100 V; C/C: ± 30 %
ESR 3 x spec. limit
Z 3 x spec. limit
I
L5
spec. limit
no short or open circuit,
no visible damage
total failure percentage:
U
R
100 V: 1 %;
U
R
> 100 V: 3 %
Shelf life
(storage at
high temperature)
IEC 60384-4/
EN130300
subclause 4.17
T
amb
= 85 °C; no voltage applied; 500 h
after test: U
R
to be applied for 30 min, 24 h to 48 h
before measurement
C/C: ± 10 %
ESR 1.2 x spec. limit
I
L5
2 x spec. limit
2.4
2.3
2.2
2.1
2.0
1.9
I
A
I
R
1.8
1.7
1.5
1.6
1.4
1.3
1.2
1.1
1.0
0.8
0.5
0.0
MGA453
life multiplier
40 50 60 70 80 90
T
amb
(°C)
(1)
45
30
20
15
10
8
5
2.5
4
3
2
1.5
1.2
1
60
I
A
= Actual ripple current at 100 Hz
I
R
= Rated ripple current at 100 Hz and 85 °C
(1)
Useful life at 85 °C and I
R
applied: 12 000 h