Datasheet

www.vishay.com For technical questions, contact: aluminumcaps1@vishay.com
Document Number: 28329
194 Revision: 02-Sep-10
041 - 043 ASH
Vishay BCcomponents
Aluminum Capacitors
Axial Standard, High Voltage
Table 4
TEST PROCEDURES AND REQUIREMENTS
TEST PROCEDURE
(quick reference)
REQUIREMENTS
NAME OF TEST REFERENCE
Endurance IEC 60384-4/
EN130300
subclause 4.13
T
amb
=85C; U
R
applied;
caseØ D x L:
6.5 x 18 to 10 x 25 mm:
2000 h;
10 mm x 30 mm to 21 mm x 38 mm
8000 h (450 V: 5000 h)
U
R
= 160 V; C/C: ± 15 %
U
R
= 250 V to 450 V; C/C: ± 10 %
tan 1.3 x spec. limit
Z 2 x spec. limit
I
L5
spec. limit
Useful life CECC 30301
subclause 1.8.1
T
amb
=85C; U
R
and I
R
applied;
caseØ D x L:
6.5 mm x 18mm to 10 mm x 25 mm:
5000 h;
10x30to21x38mm:
15 000 h (450 V: 10 000 h)
U
R
= 160 V; C/C: ± 45 %
U
R
= 250 V to 450 V; C/C: ± 30 %
tan  3 x spec. limit
Z 3 x spec. limit
I
L5
spec. limit
no short or open circuit
total failure percentage: 3 %
Shelf life
(storage at high
temperature)
IEC 60384-4/
EN130300
subclause 4.17
T
amb
=85C; no voltage applied;
500 h
after test: U
R
to be applied for 30 min,
24 h to 48 h before measurement
C/C, tan , Z:
for requirements
see ‘Endurance test’ above
I
L5
2 x spec. limit