Datasheet

HFA08TB60S
Bulletin PD-20607 rev. B 11/00
2
Parameter Min. Typ. Max. Units
T
lead
! Lead Temperature –––– –––– 300 °C
R
thJC
Thermal Resistance, Junction to Case –––– –––– 3.5
R
thJA
" Thermal Resistance, Junction to Ambient –––– –––– 80
Wt Weight –––– 2.0 –––– g
–––– 0.07 –––– (oz)
Parameter Min. Typ. Max. Units Test Conditions
t
rr
Reverse Recovery Time ––– 18 ––– I
F
= 1.0A, di
f
/dt = 200A/µs, V
R
= 30V
t
rr1
––– 37 55 ns T
J
= 25°C
t
rr2
––– 55 90 T
J
= 125°C I
F
= 8.0A
I
RRM1
Peak Recovery Current ––– 3.5 5.0 T
J
= 25°C
I
RRM2
––– 4.5 8.0 T
J
= 125°C V
R
= 200V
Q
rr1
Reverse Recovery Charge ––– 65 138 T
J
= 25°C
Q
rr2
––– 124 360 T
J
= 125°C di
f
/dt = 200A/µs
di
(rec)M
/dt1 Peak Rate of Fall of Recovery Current –– 240 –– T
J
= 25°C
di
(rec)M
/dt2 During t
b
––– 210 ––– T
J
= 125°C
Parameter Min. Typ. Max. Units Test Conditions
V
BR
Cathode Anode Breakdown Voltage 600 ––– ––– V I
R
= 100µA
––– 1.4 1.7 I
F
= 8.0A
––– 1.7 2.1 V I
F
= 16A
––– 1.4 1.7 I
F
= 8.0A, T
J
= 125°C
––– 0.3 5.0 V
R
= V
R
Rated
––– 100 500 T
J
= 125°C, V
R
= 0.8 x V
R
Rated
D Rated
C
T
Junction Capacitance ––– 10 25 pF V
R
= 200V
Measured lead to lead 5mm from
package body
Electrical Characteristics @ T
J
= 25°C (unless otherwise specified)
Dynamic Recovery Characteristics @ T
J
= 25°C (unless otherwise specified)
A/µs
nC
A
L
S
Series Inductance ––– 8.0 ––– nH
See Fig. 3
See Fig. 2
See Fig. 1
Thermal - Mechanical Characteristics
See Fig. 5, 6
See Fig. 7
See Fig. 8
K/W
V
FM
Max Forward Voltage
µA
Max Reverse Leakage Current
I
RM
! 0.063 in. from Case (1.6mm) for 10 sec
" Typical Socket Mount