Datasheet
AC05 Safety (AC05..CS)
www.vishay.com
Vishay Draloric
Revision: 15-Jul-14
3
Document Number: 28894
For technical questions, contact: ww1resistors@vishay.com
THIS DOCUMENT IS SUBJECT TO CHANGE WITHOUT NOTICE. THE PRODUCTS DESCRIBED HEREIN AND THIS DOCUMENT
ARE SUBJECT TO SPECIFIC DISCLAIMERS, SET FORTH AT www.vishay.com/doc?91000
Note
• Surge voltage handling capability: 4 kV (10R to 20R) and 6 kV
(22R to 100R) as per IEC 61000-4-5
Notes
• Please see document “Vishay Material Category Policy”: www.vishay.com/doc?99912
• For further information, please contact: ww1resistors@vishay.com
RESISTANCE VALUE (Ω)
ENERGY IN JOULES
PULSE ENERGY CURVE FOR AC05..CS
0
10
20
30
40
50
60
10 10033 39 47 56 62 68 75 829122
FUSING CHARACTERISTICS
OF AC05..CS: 10 Ω ≤ R ≤ 100 Ω
FUSING TIME IN s
OVERLOAD POWER IN W
100 200150 2500
0
10
20
35
40
50
60
PERFORMANCE
TEST PERMISSIBLE CHANGE (R)
Climatic Category (LCT/UCT/Days) 40/200/56
Climatic Sequence, IEC 60115-1, 4.23 ± (1 % R + 0.05 )
Damp Heat, Steady State, IEC 60115-1, 4.24
(40 ± 2) °C, 56 days, (93 ± 3) % RH
± (5 % R + 0.1 )
Endurance at Room Temperature (116 % P
70
), 1000 h,
IEC 60115-1, 4.25.2
± (5 % R + 0.1 )
Endurance at UCT, 200 °C (30 % P
70
), 1000 h, IEC 60115-1, 4.25.3 ± (5 % R + 0.1 )
Resistance to Soldering Heat, IEC 60115-1, 4.18
(260 ± 5) °C, (10 ± 1) s
± (0.5 % R + 0.05 )
Robustness of Termination, IEC 60115-1, 4.16 ± (0.5 % R + 0.05 )
Short Time Overload, IEC 60115-1, 4.13
10 x Rated Power (P
40
) for 5 s
± (2 % R + 0.1 )
1.2 μs/50 μs Surge Test (Impedance of Surge Tester is 2 )
as per IEC 61000-4-5; 10 Pulses at 30 s Interval
± (5 % R + 0.1 )
Fail Safe Mains Fusing at 230 V
AC
Resistance > 100 k, fusing time < 2 s
(fusing without flame and explosion)