Datasheet
16CTQ..., 16CTQ...S, 16CTQ...-1 Series
2
Bulletin PD-20192 rev. L 01/06
www.irf.com
16CTQ060 16CTQ80 16CTQ100
16CTQ060S 16CTQ80S 16CTQ100S
16CTQ060-1 16CTQ80-1 16CTQ100-1
V
R
Max. DC Reverse Voltage (V)
V
RWM
Max. Working Peak Reverse Voltage (V)
60 80 100
Voltage Ratings
Parameters
Absolute Maximum Ratings
Parameters Values Units Conditions
I
F(AV)
Max. Average Forward (Per Leg) 8 A 50% duty cycle @ T
C
= 148°C, rectangular wave form
Current * See Fig. 5 (Per Device) 16
I
FSM
Max. Peak One Cycle Non-Repetitive 850 5µs Sine or 3µs Rect. pulse
Surge Current (Per Leg) * See Fig. 7 275 10ms Sine or 6ms Rect. pulse
E
AS
Non-Repetitive Avalanche Energy 7.50 mJ T
J
= 25 °C, I
AS
= 0.50 Amps, L = 60 mH
(Per Leg)
I
AR
Repetitive Avalanche Current 0.50 A Current decaying linearly to zero in 1 µsec
(Per Leg) Frequency limited by T
J
max. V
A
= 1.5 x V
R
typical
A
T
J
Max. Junction Temperature Range -55 to 175 °C
T
stg
Max. Storage Temperature Range -55 to 175 °C
R
thJC
Max. Thermal Resistance Junction 3.25 °C/W DC operation
to Case (Per Leg)
R
thJC
Max. Thermal Resistance Junction 1.63 °C/W DC operation
to Case (Per Package)
R
thCS
Typical Thermal Resistance, Case 0.50 °C/W Mounting surface , smooth and greased
to Heatsink (only for TO-220)
wt Approximate Weight 2 (0.07) g (oz.)
T Mounting Torque Min. 6 (5)
Max. 12 (10)
Thermal-Mechanical Specifications
Kg-cm
(Ibf-in)
Parameters Values Units Conditions
V
FM
Max. Forward Voltage Drop 0.72 V @ 8A
(Per Leg) * See Fig. 1 (1) 0.88 V @ 16A
0.58 V @ 8A
0.69 V @ 16A
I
RM
Max. Reverse Leakage Current 0.55 mA T
J
= 25 °C
(Per Leg) * See Fig. 2 (1) 7.0 mA T
J
= 125 °C
V
F(TO)
Threshold Voltage 0.415 V T
J
= T
J
max.
r
t
Forward Slope Resistance 11.07 m Ω
C
T
Max. Junction Capacitance (Per Leg) 500 pF V
R
= 5V
DC
(test signal range 100Khz to 1Mhz) 25°C
L
S
Typical Series Inductance (Per Leg) 8.0 nH Measured lead to lead 5mm from package body
dv/dt Max. Voltage Rate of Change 10000 V/ µs
(Rated V
R
)
T
J
= 25 °C
T
J
= 125 °C
Electrical Specifications
(1) Pulse Width < 300µs, Duty Cycle <2%
V
R
= rated V
R
Parameters Values Units Conditions
Following any rated
load condition and with
rated V
RRM
applied