User's Manual
Adjustable Settings:
Firing Mode (Yellow) Values 1-7 (Default is 1)
1 Semi Auto- Semi Automatic Fire; 1trigger
pull equals 1 shot.
2 Modified PSP/NXL- The first 3 shots of a
string are Semi Auto. After the 4
th
shot the marker will ramp to the rate of
fire your “Max Rate of Fire” is set to.
Once the trigger is let go and 1 second
elapses, the 3 shot Semi Auto count
restarts.
3 NXL Style Full Auto- The first 3 shots of a
string are Semi Auto. On the 4th shot
you can then hold down the trigger,
and the marker will shoot full auto at
your Max Rate of Fire.
4 Ramp Mode- When you reach the “Ramp
Activation Speed” the Marker will
ramp the rate of fire by your “Ramp
Percentage” setting, up to your Max
Rate of Fire. Factory default is when
your trigger speed reaches 5bps, the
marker will ramp up to the maximum
speed that your loader can feed.
5 Auto Response- 1 shot on the pull of the
trigger; 1 shot on the release. This
setting will make you shoot twice as
fast as you can pull the trigger.
6 Full Auto- Hold down the trigger, and the
marker will fire at your max rate of
fire, or as fast as your loader can feed.
7 Breakout Mode- In this mode, when you
turn the gun on, the first shot will
shoot full auto for as long as you hold
down the trigger. Once you release the
trigger the gun goes into “Ramp
Mode”. If you turn your marker off
and back on when in this mode, the
Breakout function will repeat.
Debounce (Green) Values 1-30 (Default is 5)
Debounce is the amount of time that the trigger has to be
released before the next trigger pull is allowed. Virtue
software incorporates our own AdvantagePB debounce
algorithm, which ensures every trigger pull is recognized.
This results in giving the user the highest rates of fire possible.
The values range from 1-50 with the default set to 5.
Ramp Activation Speed (Red)
Values 5-15 (Default is 5)
The ramp activation speed setting only affects Firing modes 4
and 7 (Ramp and Breakout Mode). The default setting is 5,
which means when the user reaches triggers speeds of 5bps,
ramping will activate, and add the percentage set in the “Ramp
Percentage” setting. The values of this setting are equivalent to
balls per second. For example, 5 = 5bps; 10 = 10bps, etc.
Ramp Percentage (Flickering Yellow)
Values 1- 21 (Default 1)
The ramp percentage setting only affects Firing modes 4 and 7
(Ramp and Breakout Mode). The default setting is 1, which
“Maxes Your Loader” as soon as the Ramp Activation Speed is
reached.
Value Percentage Value Percentage Value Percentage
1
Max Loader
8 40% 15 75%
2 10% 9 45% 16 80%
3 15% 10 50% 17 85%
4 20% 11 55% 18 90%
5 25% 12 60% 19 95%
6 30% 13 65% 20 100%
7 35% 14 70% 21 200%
Dwell (Flickering Green) Values 5-30 (Default
is 18)
Dwell is the amount of time that the solenoid will be activated.
The default is 18 milliseconds (ms), and the values range from
5 – 30 ms. Too low of a dwell setting will lead to inconsistent
velocities and drop off. Too high of a dwell will result in poor
air efficiency.
Eye Sensitivity (Flickering Red) Values 1-50
(Default is 5)
The Eye Sensitivity setting adds a small delay after the eye has
seen a ball before it allows the marker to shoot. Players using
non-force fed loaders may need to raise this setting to prevent
chopping. The default setting is 5, with 1 being the fastest (No
delay).
AMB (Flashing Yellow) Values 1-10 (Default is 3)
The Anti-Mechanical Bounce (AMB) feature allows the user to
adjust for mechanical bounce. Mechanical bounce happens
when the “kick” from having a shot fired causes the marker to
shoot additional shots after the trigger has been pulled. The
default setting is 3, which is a low AMB. This setting ranges
from 1-10 with 1 being AMB off.
ABS (Flashing Green)
Values 1 –20 (Default is 10)
The Anti-Bolt Stick (ABS) setting is the amount of dwell time
added for an ABS shot. This
setting ranges from 1 – 20
additional milliseconds of dwell, with the default set to 10.
Max Rate of Fire (Flashing Red)
Values 1-25 (Default 1)
The max rate of fire setting applies to all modes of fire. If
Dipswitch 1 is in the up or on position, the max rate of fire is
determined by this setting. If Dipswitch 1 is in the down or off
position, the rate of fire is capped at 15bps for all modes of
fire. The max rate of fire is adjustable from 10.5bps to
unlimited rates of fire. The default setting is 1, which is an
unlimited rate of fire.
Value BPS Value BPS Value BPS
1 Unlimited 10
14.50
19 19.00
2 10.50 11 15.00 20 20.00
3 11.00 12 15.50 21 21.00
4 11.50 13 16.00 22 22.00
5 12.00 14 16.50 23 23.00
6 12.50 15 17.00 24 24.00
7 13.00 16 17.50 25 25.00
8 13.50 17 18.00
9 14.00 18 18.50
For More Information Please See:
www.AdvantagePB.com
AdvantagePB LLC
103 Fulton Blvd.
Commack, NY 11725
Specifications subject to change without notice.
TM
T
TM
Proto Matrix Software
User’s Manual