User manual

30:Configuring SLA for a router
_______________________________________________________________________________________________________
Figure 100: The SLA daemon page
In the Basic Settings section, click Add. The basic settings section for SLA
Daemon appears.
Figure 101: The SLA daemon page
Check Enable.
In the Timeout for Roundtrip Timeout field, type in a time.
Select an interface on which traffic should be monitored.
Specify a destination IP address for the keepalive packets that are originated on
the LAN.
Specify a destination UDP port for the keepalive packets that are originated on
the LAN.
Scroll down to the Advanced Settings section.
In the Bin Restart Period field, type in a bin collection time.
In the Max Bin count field, type the maximum number of Bins stored on a
router.
Name Type Required Default Description
Enable
Check
box
Yes none Enables SLAD daemon.
Roundtrip
Timeout (ms)
integer Yes None
Specifies the time in milliseconds that a
packet is not replied before this timeout
_______________________________________________________________________________________________________
© Virtual Access 2015
GW1000 Series User Manual