User manual

26: Terminal Server
_______________________________________________________________________________________________________
# Forwarding timer mode (serial to network), 'idle'=timer re-started on
each received data, 'aging'=timer started on first rx
option fwd_timer_mode 'idle'
# Forwarding buffer size (serial to network)
option fwd_buffer_size 256
# Forwarding buffer size (network to serial), 0=use maximum possible
network rx buffer size
option sfwd_buffer_size 0
# Forwarding timeout in milliseconds (network to serial), 0=forward to
serial immediately
option sfwd_timeout 20
# Forwarding timer mode (network to serial), 'idle'=timer re-started on
each received data, 'aging'=timer started on first rx
option sfwd_timer_mode 'idle'
# serial device speed in baud
option speed 115200
# serial device word size (5,6,7,8)
option wsize 8
# serial device parity (0=none, 1=even, 2=odd)
option parity 0
# serial device number of stop bits (1 or 2)
option stops 1
# serial flow control mode (0=none, 1=RTS CTS, 2=XONXOFF)
option fc_mode 0
# time in milliseconds to start re-connecting after setting DTR low
option disc_time_ms 5000
_______________________________________________________________________________________________________
© Virtual Access 2015
GW1000 Series User Manual
Issue: 2.4 Page 186 of 255