User manual

26: Terminal Server
_______________________________________________________________________________________________________
Figure 83: The general tab fields part 2
Name
Type
Required
Default
Description
Enable Checkbox Yes Disabled Enabled port.
Network
Fowrarding Buffer
Size
Numeric
value
Yes 256
Forwarding buffer size (serial to
network).
Network
Forwarding Timeout
Numeric
value
Yes 30
Forwarding timeout in milliseconds
(serial to network).
Network forwarding
timer mode
Dropdown
list
Yes idle
Forwarding timer mode (serial to
network), 'idle'=timer re-started on
each received data, 'aging'=timer
started on first rx.
Serial Fowrarding
Buffer Size
Numeric
value
No 0
Forwarding buffer size (network to
serial), 0=use maximum possible
network rx buffer size.
Serial Forwarding
Timeout (ms)
Numeric
value
No 20
Forwarding timeout in milliseconds
(network to serial), 0=forward to
serial immediately.
Serial forwarding
timer mode
Dropdown
list
Yes idle
Forwarding timer mode (network to
serial), 'idle'=timer re-started on
each received data, 'aging'=timer
started on first rx.
Proxy mode Checkbox No Disabled Enable proxy mode.
Disable remote
client's local echo
(Telnet option)
Checkbox No Disbled
1=send IAC WILL ECHO Telnet
option to remote client forcing it to
disable local echo (for server mode
only).
Telnet COM port
control (RFC2217)
Checkbox No Disbled
1=enable support for Telnet COM
port control (RFC2217).
Enable HDLC
Pseudowire over
UDP (RFC4618)
Checkbox No Disabled
Enables HDLC Pseudowire over UDP
support (based on RFC4618), if set
to 1, also set udpMode 1.
_______________________________________________________________________________________________________
© Virtual Access 2015
GW1000 Series User Manual
Issue: 2.4 Page 179 of 255