18: Automatic operator selection
_______________________________________________________________________________________________________
In the Exclusive Group field type in 3g.
From the dropdown menu, select the Choose Minimum ifup Interval option.
From dropdown menu, select the Interface Start Timeout option.
From dropdown menu, select the Signal Threshold option.
All available WAN interface options are described in the table below.
Name Type Required Default Description
Health Monitor
Interval
Dropdown menu Yes 10 sec Interval used to
monitor Signal
strength
Health Monitor
ICMP Host(s)
Dropdown menu No none Target IP address
for ICMCP
packets
Health Monitor
ICMP Timeout
Dropdown menu Yes 3 sec ICMP timeout
Attempts Before
WAN Failover
Dropdown menu Yes 3 Number of fail
attempts of
Health Monitor
before interface
is torn down
Attempts Before
WAN Recovery
N/A N/A N/A N/A
Priority Number Yes 0 Higher value is
higher priority
Minimum ifup
Interval
Dropdown menu Yes 300 sec Minimum interval
between two
successive
interface start
attempts
Interface Start
Timeout
Dropdown menu Yes 40 sec Time for interface
to startup
Signal Threshold
(dBm)
Dropdown menu Yes -115 if signal is lower
than this then is
marked as fail
18.3.1.3 Setting options for automatically created interfaces
From the top menu on the web interface page, select Services ->Mobile
Manager. The Mobile Manager page appears.
_______________________________________________________________________________________________________
© Virtual Access 2015
GW1000 Series User Manual
Issue: 2.4 Page 113 of 255