Installation Manual

Maintenance
4
2.2 Cleaning and Replacing Quartz Sleeve
Note: If water contains any hardness, minerals (calcium or magnesium), iron or manganese, the quartz sleeve will require
periodic cleaning.
Prerequisites:
Shut off water supply and drain all lines.
Remove the UV lamp. Refer to Section 2.1.
Procedure:
1
1
2
1
2
3
All models:
Remove the top retaining nut
and O-ring.
Remove the bottom retaining
nut, Spring and loosen the O-
ring to drain the water.
Note: Ensure that the quartz
sleeve does not slide
2
Remove the quartz sleeve
from the UV chamber.
3
Mild
Acid
Clean the quartz sleeve with
a cloth soaked in CLR,
vinegar or some other mild
acid and then rinse with
water.
4
1
2
1
2
3