Installation Manual
Maintenance
4
2.2 Cleaning and Replacing Quartz Sleeve
Note: If water contains any hardness, minerals (calcium or magnesium), iron or manganese, the quartz sleeve will require
periodic cleaning.
Prerequisites:
• Shut off water supply and drain all lines.
• Remove the UV lamp. Refer to Section 2.1.
Procedure:
1
1
2
1
2
3
All models:
• Remove the top retaining nut
and O-ring.
• Remove the bottom retaining
nut, Spring and loosen the O-
ring to drain the water.
Note: Ensure that the quartz
sleeve does not slide
2
• Remove the quartz sleeve
from the UV chamber.
3
Mild
Acid
• Clean the quartz sleeve with
a cloth soaked in CLR,
vinegar or some other mild
acid and then rinse with
water.
4
1
2
1
2
3
All models:
• Re-insert the quartz sleeve
with O-ring(s), Sp
ring, and
retaining nut(s).
• Hand tighten the retaining
nut(s), taking care not to
over-tighten.
• When service is complete,
assemble the prerequisites in
the reverse order of
disassembly
.