User Manual
Installation
8
Prerequisites:
• Determine appropriate indoor location of the controller and chamber. Refer to Figure 3.
• Ensure adequate clearance above chamber to allow for removal of the lamp and 
sleeve.
• Make s
ure to turn off the main water supply.
• Mount the system to the wall with appropriate lag bolts through the two mounting holes located on the meta
l bracket.
The supplied lag bolts are suitable for attachment to wood. (Attachments to other materials will require purchasing of
alt
ernative hardware).
• Make all necessary plumbing connections. Refer to Figure 3.
Procedure:
1
• Screw chamber clamp(s) to
the wall (
#10 scr
ews
recommended.)
2
2
• Insert chamber and tighten
clamp(
s)
.
•
Make
all necessary plumbing
connections. Refer to
Section
2.1.
3
• Mount controller mounting
bracket to wall u
s
ing four #8
screw
s (not provided).
4
• Slide controller onto mounting 
bracket.
5
• Insert the reference card
between contr
oller 
and
mounting bracket.
Not
e: 
Outlet must be
protected by a Ground Fault
Circuit Int
errupter (GFCI).
6
• Connect power cord to 
controller.
• DO NOT connect the power 
cord to the GFCI outlet at this 
time. 
7
•  Place O-ring on the sleeve as 
shown. Insert the sleeve
 into
the chamber as shown in
step 8
.
8
• Ensure quartz sleeve is
proper
ly centered in the
chamber.