Specifications

Viper Installation and Operators Manual 2.08
62
The following table discusses the alarms and the conditions that will set off the alarm.
Alarm Condition
Off Rate
This alarm activates when the actual application rate differs from
the specified percentage rate for more than five seconds, This
alarm activates only when the system is in Auto mode. The
alarm automatically clears when the target rate and actual rate
are within the specified range or when the product mode is
switched to either Manual or Off.
Low Limit
This alarm activates when the volume per minute has dropped
below the specified limit. This alarm activates only when the
system is in Auto Mode. The alarm automatically clears when
the volume per minute rises above the specified limit or when the
product mode is switched to either Manual or Off.
Low Tank
This alarm activates when the tank volume has dropped below the
specified limit. The alarm can be cleared when you either enter a
value that is above the low tank value or when you enter a zero in
the Low Tank field.
Flow/Shaft
For an injection application, the Flow alarm is active. This alarm
activates to indicate a loss of product flow. For a granular
application, the Shaft alarm is active. This alarm activates when
the shaft sensor in a granular application does not detect shaft
rotation. You must troubleshoot the system to determine the
cause of the alarm and clear it.
Vac/Bin
For an injection application, the Vac alarm is active. This alarm
activates when the vacuum sensor detects a vacuum in the tank.
You must troubleshoot the system to determine the cause of the
alarm and clear it. For a granular application, the Bin alarm is
active. This alarm activates when the bin level sensor detects
that the granular level in the bin drops below the sensor.
Dual Flow
This alarm activates for an injection application system when the
flow switch monitor and the actual flow readings are out of the
specified tolerance. This alarm also activates when Gran 3 is
selected as the application type and the rates sensed by the dual
encoders are out of the specified tolerance.
Zero Speed
This alarm activates when the speed of the vehicle drops below
0.7 MPH and the Zero Shutoff function is enabled. Cycle the
master boom switch to clear the alarm and resume product
control.