Specifications
Manual # 016-0159-894 Rev H 01/07
57
2-Setting Up the
Controller Area
The following valves are commonly used:
The following table lists a brief description of each application type:
Valve Description
Standard
Select this type when using a standard valve. This is a
butterfly-type valve used in liquid applications. The valve
stays at the current setting when the control signal is
removed. This selection is also used when the product i
s
being controlled by a CAN Motor Control.
Fast
Same as the Standard valve, but can change setting at a
higher rate.
Fast Close
A fast valve that automatically closes when the boom
master switch is in the 'off' position.
PWM
This valve uses pulse width modulation to control the
speed of a hydraulic motor. Typically used to drive a
liquid pump.
PWM Close
PWM valve that closes completely when the master
boom switch is in the 'off' position. Typically used to
control a hydraulic motor to a spreader apron.
Application Type Description
Liquid Liquid Sprayer
Gran 1 Single-belt bed granular system
Gran 2 Split-belt bed granular system
Gran 3 Split-belt bed granular system with dual encoders
Spinner Spinner control on granular system