Specifications
Viper Installation and Operators Manual 2.08
46
5. Weigh the machine and enter the starting weight of the machine.
Note: You can either weigh the machine before and after the dump
test or you can weigh the dumped product after the test. If you are
going to weigh the amount of product dumped, enter zero in the start
weight.
6. Press the Dump Product button. A Product Dump Warning screen will
appear.
Important: Make sure no one is near the machine where the
product will be expelled. Also make sure the belt is full of
product before you start. If the belt is not full, you will get an
incorrect result.
Important: If you plan to weigh the product dumped, be sure
the weight box or loader is in place and that no product will be
spilled on the ground.
7. Press the OK button to begin dumping the product. The Spreader Constant
Calibration screen will appear. The belt will begin to move and the product will
begin dumping until the system determines that the selected test amount is
dumped.