Specifications
Manual # 016-0159-894 Rev H 01/07
323
A P P E N D I X
I
CONTROLLING SPINNER RPM
For spinner box machines, you can use a CAN control node capable of controlling
spinner speed.
Valve Type
Select the Valve Type for the machine you are using.
Application
Select Spinner, for the application type. If Spinner does not show up on the applica-
tion rate, you may not have a CAN control node capable of controlling spinner
applications. Check the CAN control node and install a node that is capable of
spinner control.
Meter Cal
The machine should be configured with a magnetic pickup coil mounted near the bolt
heads on the spinner. Calculate the meter cal by multiplying the number of pulses
(bolt heads) per revolution by 10.
For example:
N = Number of bolt heads on spinner
Meter Cal = N x 10
If
N = 4
Then
Meter Cal = 4 x 10 = 40
Spreader Constant
The spreader constant should be set to 0.
Rate Cal
The Rate Cal should be set to the desired RPM of the spinner.