The chart below shows examples of different tips and configurations:
Tip Liquid Capacity Capacity
Color Pressure Nozzle Nozzle
in PSI in GPM in oz./min.
80 deg. 110 deg. 5 MPH 6 MPH 7 MPH 8 MPH
Yellow XR8002 XR11002 15 .12 15 7.3 6.1 5.2 4.5
20 .14 18 8.4 7.0 6.0 5.3
30 .17 22 10.3 8.6 7.4 6.4
40 .20 26 11.9 9.9 8.5 7.4
60 .25 32 14.6 12.1 10.4 9.1
Blue XR8003 XR11003 15 .18 23 10.9 9.1 7.8 6.8
20 .21 27 12.6 10.5 9.0 7.9
30 .26 33 15.4 12.9 11.0 9.7
40 .30 38 17.8 14.9 12.7 11.1
60 .37 47 22.0 18.2 15.6 13.6
Red XR8004 XR11004 15 .24 31 14.5 12.1 10.4 9.1
20 .28 36 16.8 14.0 12.0 10.5
30 .35
45 21.0 17.2 14.7 12.9
40 .40 51 24.0 19.8 17.0 14.9
60 .49 63 29.0 24.0 21.0 18.2
Brown XR8005 XR11005 15 .31 40 18.2 15.2 13.0 11.4
20 .35 45 21.0 17.5 15.0 13.1
30 .43 55 26.0 21.0 18.4 16.1
40 .50 64 30.0 25.0 21.0 18.6
60 .61 78 36.0 30.0 26.0 23.0
Tip No. Gallons Per Acre - 20" spacing
The flow rate of spraying must be within the range of that specified for the flow
meter. The following table displays the flow meter, range, and average calibration
number.
Flow Meter Model Flow Range Average Meter Cal Valu
e
RFM 5 0.05 to 5 GPM 5500
RFM 15 F 0.3 to 15 GPM 1750
RFM 60P/S 1 to 60 GPM 720
RFM 100 3 to 100 GPM 700
RFM 200/200 Poly 15 to 200 GPM 164
RFM 400 25 to 400 GPM 80
Calculating
Meter
Calibrations
for Liquid
Applications
The flow meter calibration value is stamped on the tag that is attached to each flow
meter. Use this number when programming Viper for the calibration.
Verifying
Flow Rate
Limits